GAS VALVES, TUBING,

GAS VALVES, TUBING,

THERMOSTATS, REGULATORS

AND SOLENOIDS

Burner Manifold Assembly (GHCB40)

WARNING: SHUT OFF THE GAS BEFORE SERVICING.

WARNING: ALL GAS JOINTS DISTURBED DURING SERVICING MUST BE CHECKED FOR LEAKS. CHECK WITH SOAP AND WATER SOLUTION (BUBBLES). DO NOT USE AN OPEN FLAME.

1.Remove the manifold cover assembly as outlined in Covers, Panels and Handles.

2.Disconnect the burner tubing from the burner valves.

3.Disconnect the pilot supply tubing from the pilot valve.

4.Remove the two burner valves from the burner manifold assembly.

5.Remove the pilot valve from the burner manifold assembly.

6.Disconnect the oven gas supply tube from the burner manifold assembly.

NOTE: For proper alignment of the gas tubing, make sure you do not change the position of the stop nuts.

7.Remove the two nuts and two washers from the threaded rod.

8.Hold the burner manifold assembly and remove the two bolts, manifold holding bracket and two washers from the broiler.

9.Reverse the procedure to install.