Vulcan-Hart ML-052202, ML-052211, ML-052208, ML-052200 Lever Arm Assembly All Models, Upper, Lower

Models: GHMCB44 GHIR44 GHCB44 HCB1 IR2(B) HCB2(B) ML-052202 GHCB40 IR1 ML-52201 ML-052214 ML52210 ML-052213 ML-052200 ML-052208 ML-052211

1 32
Download 32 pages 43.37 Kb
Page 25
Image 25
LEVER ARM ASSEMBLY

LEVER ARM ASSEMBLY

(ALL MODELS)

Upper

WARNING: SHUT OFF THE GAS BEFORE SERVICING.

WARNING: ALL GAS JOINTS DISTURBED DURING SERVICING MUST BE CHECKED FOR LEAKS. CHECK WITH SOAP AND WATER SOLUTION (BUBBLES). DO NOT USE AN OPEN FLAME.

1.Remove the grid carriage assembly as outlined in Grid Carriage Assembly.

2.Remove the two cotter pins and washers from the upper lever arm assembly.

3.Remove the upper lever arm assembly from the two brackets.

4.Reverse the procedure to install.

Lower

WARNING: SHUT OFF THE GAS BEFORE SERVICING.

WARNING: ALL GAS JOINTS DISTURBED DURING SERVICING MUST BE CHECKED FOR LEAKS. CHECK WITH SOAP AND WATER SOLUTION (BUBBLES). DO NOT USE AN OPEN FLAME.

1.Remove the grid carriage assembly as outlined in Grid Carriage Assembly.

2.Remove two screws and the lower lever cover from the broiler.

– 25 –

Page 25
Image 25
Vulcan-Hart ML-052202, ML-052211, ML-052208, ML-052200, ML-052213, ML52210, IR1 Lever Arm Assembly All Models, Upper, Lower