Vulcan-Hart IR2(B), ML-052211, ML-052208, ML-052200, ML-052213 IR1 and IR2B, Blower Switch GHIR44

Models: GHMCB44 GHIR44 GHCB44 HCB1 IR2(B) HCB2(B) ML-052202 GHCB40 IR1 ML-52201 ML-052214 ML52210 ML-052213 ML-052200 ML-052208 ML-052211

1 32
Download 32 pages 43.37 Kb
Page 27
Image 27
IR1 and IR2(B)

8.Disconnect the electrical wires.

9.Remove the blower and motor from the broiler.

10.Reverse the procedure to install.

IR1 and IR2(B)

WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES.

WARNING: SHUT OFF THE GAS BEFORE SERVICING.

1.Remove the screws and the bracket and the blower and motor.

2.Remove the screws and nuts from the air duct and the blower and motor.

3.Carefully remove the screws from the blower and motor and the brackets.

4.Carefully remove the air duct from the blower and motor.

5.Note the location and connection of the electrical wires.

6.Disconnect the electrical wires from the blower and motor.

7.Remove the blower and motor from the broiler.

8.Reverse the procedure to install.

Blower Switch (GHIR44)

WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES.

WARNING: SHUT OFF THE GAS BEFORE SERVICING.

1.Remove the manifold cover assembly as outlined in Covers, Panels and Handles.

2.Remove the nut from the manifold cover assembly and the switch.

3.Note the location and connection of the electrical wires.

4.Disconnect the electrical wires.

5.Reverse the procedures to install.

– 27 –

Page 27
Image 27
Vulcan-Hart IR2(B), ML-052211, ML-052208, ML-052200, ML-052213, ML52210, ML-052214, ML-52201 IR1 and IR2B, Blower Switch GHIR44