Image 21
Thermostat (GHCB40)

6.Remove the two bolts from the pilot outage protection valve and the bracket.

7.Disconnect the pilot outage protection valve from the union and the thermostat.

8.Remove the pilot outage protection valve and the ignitor wire from the broiler.

9.Reverse the procedure to install.

Thermostat (GHCB40)

WARNING: SHUT OFF THE GAS BEFORE SERVICING.

WARNING: ALL GAS JOINTS DISTURBED DURING SERVICING MUST BE CHECKED FOR LEAKS. CHECK WITH SOAP AND WATER SOLUTION (BUBBLES). DO NOT USE AN OPEN FLAME.

1.Remove the control panel cover as outlined in Covers, Panels and Handles.

2.Note the location and position of the temperature probe in the oven.

3.Disconnect the thermostat from the pilot outage protection valve and from the oven burner tubing.

4.Remove the temperature probe from the oven.

5.Remove the thermostat with the temperature probe from the broiler.

6.Reverse the procedure to install.

– 21 –

Page 21
Image 21
Vulcan-Hart ML-052214, ML-052211, ML-052208, ML-052200, ML-052213, ML52210, ML-52201, IR1, ML-052202, HCB2(B) Thermostat GHCB40