Vulcan-Hart ML-052213, ML-052211, ML52210 Burner Manifold Assembly GHIR44, Oven Pilot Valve GHCB40

Models: GHMCB44 GHIR44 GHCB44 HCB1 IR2(B) HCB2(B) ML-052202 GHCB40 IR1 ML-52201 ML-052214 ML52210 ML-052213 ML-052200 ML-052208 ML-052211

1 32
Download 32 pages 43.37 Kb
Page 19
Image 19
Burner Manifold Assembly (GHIR44)

Burner Manifold Assembly (GHIR44)

WARNING: SHUT OFF THE GAS BEFORE SERVICING.

WARNING: ALL GAS JOINTS DISTURBED DURING SERVICING MUST BE CHECKED FOR LEAKS. CHECK WITH SOAP AND WATER SOLUTION (BUBBLES). DO NOT USE AN OPEN FLAME.

1.Remove the manifold cover assembly as outlined in Covers, Panels and Handles.

2.Disconnect the drop pipe from the burner manifold assembly

NOTE: For proper alignment of the gas tubing, make sure you do not change the position of the stop nuts.

3.Remove the two nuts and two washers from the threaded rod.

4.Hold the burner manifold assembly and remove the two bolts, manifold holding bracket and two washers from the broiler.

5.Reverse the procedure to install.

Oven Pilot Valve (GHCB40)

WARNING: SHUT OFF THE GAS BEFORE SERVICING.

WARNING: ALL GAS JOINTS DISTURBED DURING SERVICING MUST BE CHECKED FOR LEAKS. CHECK WITH SOAP AND WATER SOLUTION (BUBBLES). DO NOT USE AN OPEN FLAME.

1.Remove the control panel cover as outlined in Covers, Panels and Handles.

2.Disconnect the pilot tubing from the oven pilot valve.

3.Remove the oven pilot valve from the gas supply tube.

4.Reverse the procedure to install.

Oven Burner Valve (GHCB40)

WARNING: SHUT OFF THE GAS BEFORE SERVICING.

WARNING: ALL GAS JOINTS DISTURBED DURING SERVICING MUST BE CHECKED FOR LEAKS. CHECK WITH SOAP AND WATER SOLUTION (BUBBLES). DO NOT USE AN OPEN FLAME.

1.Remove the control panel cover as outlined in Covers, Panels and Handles.

– 19 –

Page 19
Image 19
Vulcan-Hart ML-052213, ML-052211, IR1 Burner Manifold Assembly GHIR44, Oven Pilot Valve GHCB40, Oven Burner Valve GHCB40