GBD_GBDF SERIES GAS FRYERS

ŠWhen installing a quick disconnect you must also install a means for limiting the movement of the fryer. This device will prevent the gas line or quick disconnect from being strained. The restraining device should be attached to the cutout on the back panel. See illustration for location.

ŠIn Australia, use only the caster supplied by the manufacturer for the fryer device. The fryer must be installed using a hose assembly restraining device to limit the movement of the appliance in accordance with AS1869.

ŠThe fryer must be installed with a connector (not supplied by Vulcan) complying with the above codes.

ŠThe fryer must be installed with restraining means to guard against transmission of strain to the connector. See illustration.

ŠThe fryer must be installed with the casters provided.

ŠIf the restraint is ever to be disconnected, first turn the gas supply off.

ELECTRICAL CONNECTION

ŠThe fryer comes with a NEMA 15-5P plug that requires 120 Volt service. Plug in the wire connection into an approved outlet.