Vulcan-Hart 1G6BD ML-136648, ML-136654 Boil Out Procedure, Thermal Overload Protection Button

Models: 1G6BD 1G4BD ML-136647 2G8BDF 1G6BD ML-136648 1G8BD ML-136649 1G4BD 2G4BDF 2G6BDF 2XG4BDF 3G4BDF 3G6BDF 2XG8BDF 3G8BDF 4G6BDF 4G8BDF 2XG6BDF 4G4BDF ML-136655 ML-136649 ML-136650 ML-136653 ML-136647 ML-136648 ML-136652 ML-1 ML-136651 ML-136681 ML-136657 ML-136656 ML-136654

1 26
Download 26 pages 30.3 Kb
Page 25
Image 25
BOIL OUT PROCEDURE:

GBD_GBDF SERIES GAS FRYERS

BOIL OUT PROCEDURE:

Use the Boil Out By-Pass™ drain extension allowing the boil out solution to exit the fry tank without using the filtering system. Do not allow water to run through the motor / pump. Drain the boil out solution into a bucket or place a hose on the end of the drain extension allowing the other end to flow into a floor drain. In Fig. 6 the arrow is pointing to the drain extension. It is threaded into the top coupling of the oil drain tube. Drain extension needs to be only hand tightened.

THERMAL OVERLOAD PROTECTION BUTTON:

The motor/pump supplied with the filtering system has a thermal overload protection circuit that senses when excess heat occurs due to filtering for long periods of time or under heavy load prior to discarding debris buildup. If the thermal overload protection is tripped, wait 5 minutes and then reset the motor by pushing in the red button. The arrow in Figure 7 shows the location of the reset button; located on the front off the motor / pump facing towards you.

VULCAN-HART

Fig. 6

Fig. 7

F-32934 Rev. B (June 2008)

-25-

Page 25
Image 25
Vulcan-Hart 1G6BD ML-136648, ML-136654, ML-136656, ML-136657, 4G4BDF Boil Out Procedure, Thermal Overload Protection Button