5.Pour deliming solution into the steam generator slowly to avoid spillage.

6.Remove funnel from delime port then rinse port with clean water.

7.Lightly coat delime port threads with Petrol- Gel then install delime port cap. Cap must be installed and tightened securely at all times.

8.Turn power switch ON.

9.When ready light comes on, turn cooking timer on for 3 minutes to delime the steam tubes and nozzles.

10.After 40 minutes, turn power switch OFF and allow steam generator to completely drain, 5 minutes.

11.Rinse steam generator with clean water:

A.Turn power switch ON. When ready light comes on, turn cooking timer on for 3 minutes to rinse the steam tubes and nozzles.

B.Turn power switch OFF and allow steam generator to completely drain.

C.Turn cooking timer to OFF.

D.Repeat steam generator rinse one time.

12.Clean exterior and interior using a mild solution of soap and water. Rinse with clean water then dry with a soft cloth.

13.Leave compartment door open when not in use.

14.The steamer is ready for operation or shutdown.

Basic Unit (Manual Drain Lever)

Note: This procedure is not intended to take the place of a water treatment program.

1.Pull drain lever out to open generator drain and turn unit off. Wait 5 minutes for steam generator to completely drain.

2.Turn cooking timer to OFF.

3.Prepare deliming solution according to the instructions on the deliming material package. Follow all manufacturer's instructions.

4.Remove delime port cap on top of unit and insert funnel into delime port.

5.Lightly coat delime port threads with Petrol- Gel.

6.Push drain lever in to close the drain valve and turn the unit on.

7.Pour deliming solution into the steam generator slowly to avoid spillage.

8.Immediately remove funnel from delime port then rinse port with clean water.

9.Immediately install delime port cap. Cap must be installed and tightened securely at all times.

Note: Steps 6, 7, 8 and 9 must be completed within a 5-minute time period.

10.After 30 minutes, turn cooking timer on for 3 minutes to delime the steam tubes and nozzles.

11.After 50 minutes, pull drain lever out to turn the unit off and allow steam generator to completely drain, 5 minutes.

12.Rinse steam generator with clean water:

A.Push drain lever in to close drain and turn power on. Wait 20 minutes then turn cooking timer on for 30 seconds to rinse the steam tubes and nozzles.

B.Pull drain lever in and allow steam generator to completely drain.

C.Turn cooking timer to OFF.

D.Repeat steam generator rinse one time.

13.Clean exterior and interior using a mild solution of soap and water. Rinse with clean water then dry with a soft cloth.

14.Leave compartment door open when not in use.

15.The steamer is ready for operation or shutdown.