C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS

TROUBLESHOOTING

SYMPTOMS

POSSIBLE CAUSES

REMEDY

 

 

 

 

 

Steamer not steaming

No main power source

Check the power source.

 

 

Power switch in OFF position

Set power switch to the ON

 

 

(Professional)

position.

 

 

Handle out (OFF) position (Basic)

Push handle in.

 

 

Water not being supplied to

Refer to symptom WATER NOT

 

 

steamer

BEING SUPPLIED TO STEAMER.

 

Steamer not heating/

Excessive lime build up in the

Descale the steamer (see

 

steaming properly

steamer

REMOVAL OF LIME SCALE

 

 

 

DEPOSITS).

 

Door leaks

Damaged door gasket

Check door gasket for damage.

 

 

Improper drain

If adjustment is needed, contact

 

 

your Authorized Vulcan-Hart

 

 

Plugged drain

Servicer.

 

 

 

 

 

Damage to gasket sealing surface

 

 

 

 

 

 

Water accumulates in

Plugged drain or screen

Clear compartment cavity

 

compartment

 

screen. If symptom persists,

 

 

 

contact your Authorized Vulcan-

 

 

 

Hart Servicer.

 

 

Unit not leveled properly

See leveling instructions in the

 

 

 

installation section of this

 

 

 

manual.

 

 

Drain clogged

Unclog drain.

 

 

 

 

 

Water not being supplied

Water supply valve is off

Turn valve on.

 

to steamer

Water pressure low

Check water supply pressure.

 

 

 

 

Water filter is plugged

Refer to water filter manual. If

 

 

 

symptom persists, contact your

 

 

 

Authorized Vulcan-Hart Servicer.

 

 

Valve inlet screen clogged

Contact your Authorized Vulcan-

 

 

 

Hart Servicer.

 

 

 

 

 

 

 

 

 