ELECTRICAL CONNECTION

C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS

ELECTRICAL CONNECTION

WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.

The wiring diagram is located on the right side panel as you face the steamer. This steamer is hard wired.

Total

Volts

Hz

Ph

KW Per Phase

 

Rated Amps

 

 

Circuit

Fuse

90°C

 

KW

 

 

 

 

 

 

 

3-Phase Amps Per Line

Single

Size

Size

Copper

 

 

 

 

 

 

 

 

 

 

 

 

 

Phase

Amps

or

Min.

 

 

 

 

 

L1-L2

L2-L3

 

L3-L1

L1

L2

 

L3

 

 

 

 

 

 

 

 

 

Circuit

Wire

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Breaker

Size

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Size*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Amps)

 

 

8.5

208

50/60

1

 

 

 

 

 

 

 

 

40.87

60

60

8

 

8.5

240

50/60

1

 

 

 

 

 

 

 

 

35.42

50

50

8

 

8.5

208

50/60

3

4.25

2.12

 

2.12

26.54

26.54

 

17.70

 

35

35

10

 

8.5

240

50/60

3

2.83

2.83

 

2.83

20.50

20.50

 

20.50

 

30

25

10

 

8.5

480

50/60

3

2.83

2.83

 

2.83

10.30

10.30

 

10.30

 

15

15

16

 

9.25

208

50/60

1

 

 

 

 

 

 

 

 

43.57

60

60

6

 

9.25

240

50/60

1

 

 

 

 

 

 

 

 

38.54

50

50

8

 

9.25

208

50/60

3

4.25

2.69

 

2.12

26.54

28.88

 

20.04

 

35

35

10

 

9.25

240

50/60

3

2.83

3.58

 

2.83

20.45

23.15

 

23.15

 

30

30

10

 

9.25

480

50/60

3

2.83

3.58

 

2.83

10.21

11.57

 

11.57

 

15

15

16

 

15

208

50/60

1

 

 

 

 

 

 

 

 

72.12

90

90

4

 

15

240

50/60

1

 

 

 

 

 

 

 

 

62.50

75

75

6

 

15

208

50/60

3

7.50

3.75

 

3.75

46.84

46.84

 

31.23

 

60

60

6

 

15

240

50/60

3

5.00

5.00

 

5.00

36.08

36.08

 

36.08

 

50

50

8

 

15

480

50/60

3

5.00

5.00

 

5.00

18.04

18.04

 

18.04

 

25

25

14

 

15.75

208

50/60

1

 

 

 

 

 

 

 

 

74.82

90

90

4

 

15.75

240

50/60

1

 

 

 

 

 

 

 

 

65.63

80

80

4

 

15.75

208

50/60

3

7.50

4.31

 

3.75

46.84

49.18

 

33.57

 

60

60

6

 

15.75

240

50/60

3

5.00

5.75

 

5.00

36.08

38.79

 

38.79

 

50

50

8

 

15.75

480

50/60

3

5.00

5.75

 

5.00

18.04

19.40

 

19.40

 

25

25

14

 

2002 National Electric Code

*Dual Element Time-Delay Fuse or Inverse Time Circuit Breaker

Circuit Size (minimum) & Fuse/Circuit Breaker Size (maximum) compiled in accordance with the National Electrical Code (ANSI/NFPA 70), 2002 Edition.

— 7 —