VXI SM8000 Relay Optical Module’s Data Attenuation Level, Register 02 thru 08 - Read and Write

Models: SM8000

1 74
Download 74 pages 4.14 Kb
Page 56
Image 56
Relay (Optical Module’s Data (Attenuation Level))

VXI Technology, Inc.

 

Relay (Optical Module’s Data (Attenuation Level))

 

Register 02 thru 08 – Read and Write

ADDR

Plug-In LA+0x002 – 0x008

 

 

The SM8000 can alternatively drive up to 4 optical multi switch or

 

 

attenuator modules. Module one is addressed by writing a 16-bit

 

 

word to address LA+0x002; module two is controlled by writing

 

 

to address LA+0x004 and so on.

 

 

When controlling the multi switch modules, data bits D4 (MSB)-

 

 

D0 (LSB) are used to pass the channel selection data directly to

 

 

the optical module. See the configuration information for the

 

16 Bit Data Word to

specific optical module that is installed in the SM8000.

 

 

D15-D0

be sent to Optical

For multi switch modules, these addresses are both read and write.

Multi Switch or

 

 

 

Attenuator

When controlling attenuator modules D15 (MSB)-D0 (LSB) are

 

 

 

 

used to pass the 16 bit control word to the optical module.

 

 

Writing to this register initiates the transfer of data to the optical

 

 

module.

 

 

For attenuator modules, these addresses are write only.

 

 

See typical Optical Attenuator control example.

 

Relay (Optical Module’s Data (Attenuation Level))

 

 

Register 0A thru 0C – Read

ADDR

Plug-In LA+0x00A – 0x00C

 

 

 

Queries of the optical attenuator module may be acquired through

 

 

 

reading of these registers.

 

 

 

When querying attenuator modules D15 (MSB) - D0 (LSB) are

 

 

 

used to read the three 8-bit data bytes from the optical module.

 

16 Bit Data Word to

 

Once the optical module has been queried, these registers may be

 

 

read to receive the data retrieved from the optical module. Address

D15-D0

be read back from

 

 

0C will read back the most significant byte, and the address 0A

 

Optical Attenuator

 

 

 

will read back the middle and least significant byte.

 

 

 

 

 

 

Depending on the query command (see Attenuator Command Set)

 

 

 

a predefined byte count will be received back from the optical

 

 

 

module.

 

 

 

See typical Optical Attenuator control example.

56

SM8000 Series Programming

Page 56
Image 56
VXI SM8000 Relay Optical Module’s Data Attenuation Level, Register 02 thru 08 - Read and Write, Register 0A thru 0C - Read