Maintenance Instructions

cleaning

CLEANING

Enginaire™ Air Cleaner

 

A remote mounted Enginaire™ air cleaner pro-

CAUTION

vides the air filtering function. The paper filter

 

element slides over an outlet tube inside the air

 

If a pressure washer is used on the ex-

cleaner canister with radial sealing action, elimi-

nating the possibility of dust leaks due to improp-

posed working parts, avoid water on the

er filter installation. Intake design, internal baf-

electrical parts and the engine cooling

fling, and a dust ejection valve provide dust

system.

separation and automatic precleaning action.

 

 

Daily or frequent servicing of the air cleaner is not

 

Engine Air Cleaner System

required. Use the air filter restriction gauge on the

air cleaner outlet to determine when the air filter

 

Turbine Precleaner

needs servicing -- a yellow indicator will show when

the filter is overly restricting airflow into the engine.

 

Do frequently check the Turbine Precleaner

 

(located in the end cap of the air cleaner assembly)

IMPORTANT: Use only Enginaire™ air filter ele-

for free movement of the internal fan.

Shine light

ments for replacement (Walker 5090-1 or 5090-3).

into end cap to verify movement of fan with engine

Aftermarket filters may not seal properly or filter effi-

running.

 

 

ciently.

 

 

 

Enginaire™

 

 

 

Air Cleaner Cover

 

 

 

Primary Filter

 

Air Filter

 

Element

 

 

Turbine

 

Restriction Gauge

Safety

 

 

Filter

Precleaner

 

Enginaire™

 

 

 

Air Cleaner

 

 

Air Cleaner

 

 

Hose

Band

 

 

 

 

 

Clamp

 

 

 

 

 

Dust Ejection

 

 

Valve

Air Intake

Hose

 

Engine

 

 

Hose

Clamp

 

 

Engine Air Cleaner System Components

54

Page 58
Image 58
Walker MC19 manual Engine Air Cleaner System Components