INSTALLATION
9)Unscrew the pilot orifice with the allen key and replace with the LP pilot orifice in the kit.
Burner Orifice
10)Remove burner orifice with a 1/2" wrench and discard. Use a wrench to hold on to the elbow behind the orifice.
11)Reinstall new burner orifice LP stamped #50 and tighten.
12)Reverse steps 4) to 2).
13)Attach the Conversion label "This unit has been converted to Propane" on top of the Serial # decal. E63/E65: Part #175
E63/E65 Conversion Decal: 908-175
14)Replace yellow "Natural Gas" label with red "Propane" label
15)Check for gas leaks.
16)Check inlet and outlet pressures.
17)Check operation of flame control.
18)Check for proper flame appearance and glow on logs.
Reduction Kit to Lower Btu Rating for Emerald
Natural Gas - Kit #: 260-920
Propane - Kit #
THIS CONVERSION MUST BE DONE BY A
QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
Natural Gas Conversion Kit 260-920
Contains: |
|
Qty.Part # | Description |
1
1 | Decal "Converted to | |
|
| 27,000 Btu" |
1 | Instruction Sheet | |
Propane Conversion Kit | ||
Contains: |
| |
Qty.Part # | Description | |
1 | Burner Orifice #52 (Propane) |
1
29,000 Btu"
1
1) Shut off the gas supply.
2)Open the valve door and remove the control panel.
3)Open the front door. Open the right side door and there is a cutout in the heat shield through which can be seen a wing nut threaded on to a stud attached to the front door. Loosen this nut by turning it counter- clockwise.
The wing nut that holds the front door is accessible through the
4)Carefully remove the logs, embers and rock- wool.
5)Remove burner.
Note: Use a magnetic type screwdriver if possible.
Waterford | 11 |