INSTALLATION

BEFORE YOU START

Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:

INSTALLATION AND REPAIR SHOULD BE DONE BY A QUALI- FIED SERVICE PERSON. THE AP- PLIANCESHOULDBEINSPECTED BEFORE USE AND AT LEAST AN- NUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FRE- QUENT CLEANING MAY BE RE- QUIRED DUE TO EXCESSIVE LINT FROMCARPETING,BEDDINGMA- TERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPART- MENTS,BURNERSANDCIRCULAT- ING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LO- CATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY MAY CAUSE A SERIOUS HOUSE FIRE AND WILL VOID YOUR WAR- RANTY.

CHILDRENANDADULTSSHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERA- TURES, ESPECIALLY THE FIRE- PLACE GLASS, AND SHOULD STAYAWAYTOAVOIDBURNSOR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISEDWHEN THEYAREINTHESAMEROOMAS THE APPLIANCE.

CLOTHING OR OTHER FLAMMA- BLE MATERIAL SHOULD NOT BE PLACEDONORNEARTHEAPPLI- ANCE.

IMPORTANT:

SAVE THESE

INSTRUCTIONS

The EMERALD Freestanding Gas Stove must be installed in accordance with these instruc- tions. Carefully read all the instructions in this manual first. Consult the "authority having juris- diction" to determine the need for a permit prior to starting the installation.

GENERAL SAFETY

INFORMATION

1)The appliance installation must conform with local codes or, in the absence of local codes, with the current Canadian or Nation- al Gas Codes, CAN1-B149 or ANSI-223.1 Installation Codes.

2)The appliance when installed, must be elec- trically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/ NFPA 70 or CSA C22.1 Canadian Electrical Code.

3)This appliance is Listed for bedroom instal- lations when used with a Listed Millivolt Thermostat. Some areas may have further requirements, check local codes before installation.

4)This appliance is Listed for Alcove installa- tions, maintain minimum Alcove clearances as follows, minimum ceiling height of 47", minimum width of 41" and a maximum depth of 24".

5)This unit is not approved for installation into a mobile home.

6)See general construction and assembly instructions.

7)This appliance must be connected to a vent and terminate to the outside of the building envelope. Never vent to another room or inside a building.

8)Inspect the venting system annually for blockage and any signs of deterioration.

9)Any safety glass removed for servicing must be replaced prior to operating the appliance.

10)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fireplace.

11)Wear gloves and safety glasses for pro- tection while doing required maintenance.

12)Under no circumstances should this appli- ance be modified. Parts that have to be removed for servicing should be replaced prior to operating this appliance.

13)Installation and any repairs to this appliance should be done by a qualified service per- son. A professional service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually.

14)Do not strike the glass door.

15)Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance.

16)The appliance area must be kept clear and free of combustible materials, (gases and other flammable vapours and liquids).

17)This unit can be installed on a solid combus- tible surface like a wood floor as well as on carpeting.

18)Do not connect this gas appliance to chim- ney flue serving a separate sold-fuel burn- ing appliance.

19)WARNING: Operation of this appliance when not connected to a properly installed and maintained venting system or tampering with the blocked vent shutoff system can result in carbon monoxide (CO) poisoning and possible death.

20)This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.

Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

INSTALLATION

CHECKLIST

1)Check Clearances to Combustibles, page 7.

2)Install Optional Fan, page 7.

3)Install venting, page 8.

4)Make gas connections, page 9. Test the pilot. Must be as per diagram, page 17. If converting to Propane (see page 10, or if converting to lower Btu Rating (see page 11).

5)Test Gas Pressure, page 9.

6)Install log set where indicated on page 12.

7)Test for flue spillage (draft test), page 13.

6

Waterford E63-1 EMERALD Freestanding Gas Stove

Page 6
Image 6
Waterford Appliances E63-NG1 Installation, Before YOU Start, Save These Instructions, General Safety Information

E63-NG1 specifications

Waterford Appliances has long been synonymous with quality and innovation in the kitchen appliance sector. Their E63-NG1 model embodies this legacy, combining cutting-edge technology with user-friendly design to deliver an exceptional cooking experience.

The E63-NG1 is a gas range that stands out for its stunning appearance, featuring a robust stainless steel finish that not only enhances durability but also adds a touch of elegance to any kitchen. Its sleek design is complemented by heavy-duty cast iron grates, which provide a stable cooking surface that easily supports pots and pans of various sizes.

One of the standout features of the E63-NG1 is its powerful burners. The range boasts a total of five burners, including a high-output burner that generates up to 18,000 BTUs, allowing users to achieve rapid boiling and high-heat searing. Additionally, the other burners, with a variety of BTUs ranging from 6,000 to 15,000, offer versatility for simmering, sautéing, and delicate cooking tasks. This array of burners ensures that home chefs have the flexibility to tackle multiple dishes simultaneously, enhancing overall cooking efficiency.

The E63-NG1 is equipped with a spacious oven that provides ample cooking space, accommodating large roasts and multiple trays. The oven features advanced convection technology, which ensures even heat distribution for perfectly baked goods, while reducing cooking times. The inclusion of multiple oven modes, including bake, broil, and a specialized pizza mode, adds to the appliance's versatility, making it an ideal choice for various culinary styles and preferences.

Another notable characteristic of the E63-NG1 is its user-friendly digital controls. The intuitive interface allows for precise temperature settings and timing, making cooking more straightforward and enjoyable. Additionally, the oven includes dual interior lights, ensuring that users can easily monitor their food without opening the door, which helps maintain optimal cooking temperatures.

Safety is also a priority in the E63-NG1 design. It features an automatic shut-off function that activates if the oven is left on for an extended period, giving users peace of mind. The appliance also offers a reliable ignition system that ensures a quick and safe start every time.

In summary, the Waterford Appliances E63-NG1 is a perfect blend of style, functionality, and safety. With its powerful burners, spacious oven, and innovative technologies, this gas range stands out as an excellent addition to any kitchen, catering to both day-to-day meals and special culinary projects alike. Whether you're a novice home cook or an experienced chef, the E63-NG1 delivers the performance and reliability needed to inspire culinary creativity.