Waterford Appliances E63-NG1 Optional Wall Thermostat, Test For Flue Spillage, 14 GA, 50 Ft, 9 Ft

Models: E63-NG1

1 24
Download 24 pages 758 b
Page 13
Image 13
OPTIONAL WALL

INSTALLATION

3)Attach the 4 grill clips with the 4 screws but do not tighten down at this point.

4) Place the grill into position on the front of the

door, center it in the front viewing area and

The smoke should be drawn into the draft hood. If the smoke is not drawn into the draft hood, turn the unit off and check for the cause of lack of draft.

OPTIONAL WALL

THERMOSTAT

A wall thermostat may be installed if desired. Connect the wires as per the wiring diagrams. Note that the wires are connected to the "TH" on the gas valve. Use table below to determine the maximum wire length:

Note: Preferable if the thermostat is in- stalled on an interior wall.

Waterford offers an optional programmable thermostat but any 250-750 millivolt rated non- anticipator type thermostat that is CSA, ULC or UL approved may be used.

CAUTION

Do not connect the millivolt

wall thermostat wires

to the 120V wires.

Thermostat Wire Table

use the grill clips to hold it in place.

5)Tighten the screws on the grill clips.

6)Replace the glass and secure the glass clips, reversing step 2)

7)Close the front door by reversing step 1).

TEST FOR FLUE

SPILLAGE

A "spillage" test must be made before the installed unit is left with the customer. Follow the procedure below:

1)Start all exhaust fans in the home and any other gas appliances. Then close all doors and windows.

2)Light the unit and set controls to maximum.

3)After five minutes, test that there is a "pull" on the flue by placing a smoke match, cigarette or similar device which gives off smoke, on the edge of the draft hood. See diagrams.

Note: If the flue is blocked or has a strong reverse flow, the thermally actuat- ed safety switch mounted in the draft hood will automatically shut off the gas supply within about 10 minutes. If the heater turns off because of this during the spillage test, check for the

The thermally activated safety switch must be manually reset before first star- tup.

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

 

Wire Size

Max. Length

 

14 GA.

50 Ft.

 

16 GA.

32 Ft.

 

18 GA.

20 Ft.

 

20 GA.

12 Ft.

 

22 GA.

9 Ft.

 

 

 

 

 

 

 

 

OPTIONAL REMOTE

CONTROL

Use the Waterford Remote Control Kit approved for this unit. Use of other systems may void your warranty.

The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.

1)Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very im- portant). Run wires from the fireplace to that location, use Thermostat Wire Table.

2)Connect the wires as per the wiring dia- gram on page 14.

CAUTION

Do not connect the millivolt

remote control wires to the 120V

wires.

Waterford E63-1 EMERALD Freestanding Gas Stove

13

Page 13
Image 13
Waterford Appliances E63-NG1 Optional Wall Thermostat, Test For Flue Spillage, Optional Remote Control, 14 GA, 50 Ft, 9 Ft