APPENDIX C: SYSTEM TRANSACTIONS — NUMERICAL SEQUENCE

C-3

#

Message

Explanation

 

54

Device Online

ACU communicating with host.

 

55Request Manual Access Manual access command entered.

56

(Building Closed Trace)

Obsolete message

58

Repack OK

Host has loaded new database information.

59Error Setting Bldg. Mode Building mode command unsuccessful.

60

Key Activated

Key presented to activate reader — activate card enabled.

 

 

 

61

Key Deactivated

Key presented to deactivate reader — deactivate card enabled.

62

Key Not Active

Access denied — key applies to activate reader.

 

 

 

63

New Day

Host rebooted or clock has crossed 00:00.

64Remote Trans Received Dial-up device transmission received by host.

 

65

Host Dial OK

Host has called a dial-up device.

 

66

Error Dialing Remote

Download errors to remote dial-up device encountered.

 

 

 

 

 

 

67

Output Activated

Output contact manually or automatically activated.

 

68

Output Deactivated

Output contact manually or automatically deactivated.

 

 

 

 

 

 

69

Invalid PIN Entered

PIN entered incorrect.

 

70

Redundancy On

Not used at this time.

 

 

 

 

 

 

71

Redundancy Off

Not used at this time.

 

72

Host Poller Down

Not used at this time.

 

 

 

 

 

 

73

Acknowledge DB Xfer

Data successfully downloaded to target device.

 

74

Failed DB Xfer

Data download attempt to target device failed.

 

 

 

 

 

 

75

No Key Set for PIN

PIN entered without valid key presentation.

 

76

Keyholder Duress

PIN entered in reverse sequence indicating a duress situation. If

 

 

 

 

valid, access is granted.

 

 

 

 

 

 

77

Controller Comm Error

Host to local controller communication failed.

 

78

RDI Dialed In

RDI unit has dialed host and is logged in.

 

 

 

 

 

 

79

Lot Full

Optional parking function.

 

80

Max Tenant In Lot

Optional parking function.

 

 

 

 

 

 

81

Alarm Resolved

Alarm event resolved.

 

82

Enter Attended Mode

Optional parking function.

 

 

 

 

 

 

Page 160
Image 160
Westinghouse SE 6000 manual Appendix C System Transactions Numerical Sequence

SE 6000 specifications

The Westinghouse SE 6000 is an advanced digital power management system designed for comprehensive control over electrical grids and power generation facilities. Its versatility and reliability make it a favored choice among utility providers and energy managers. The SE 6000 is equipped with numerous features that enhance efficiency, safety, and operational oversight.

One of the standout features of the Westinghouse SE 6000 is its robust data analytics capability. The system employs state-of-the-art telemetry and monitoring technologies that allow for real-time data collection and analysis. This enables operators to track power usage trends, identify inefficiencies, and make informed decisions regarding energy distribution and consumption.

Another key characteristic of the SE 6000 is its support for multiple communication protocols. This compatibility ensures seamless integration with existing infrastructure and facilitates interoperability among various devices and systems. Whether using DNP3, IEC 61850, or other industry-standard protocols, users can easily connect the SE 6000 to their grid management systems.

The SE 6000 features advanced protection mechanisms that are crucial for maintaining system integrity. Its built-in protection algorithms monitor for fault conditions and automatically execute pre-configured responses, thereby minimizing downtime and ensuring uninterrupted power delivery. This proactive approach to fault management helps safeguard both equipment and personnel.

In terms of user experience, the SE 6000 boasts an intuitive interface that simplifies the complexity of power management. The graphical user interface is designed with operator ergonomics in mind, offering customizable dashboards and clear visualizations of system performance metrics. This makes it easier for operators to monitor operations and respond quickly to potential issues.

Moreover, the SE 6000 is designed to support renewable energy systems, showcasing its adaptability to the evolving energy landscape. With the increasing integration of solar, wind, and other renewable sources, this platform is geared toward facilitating grid stability and reliability in conjunction with fluctuating power outputs.

Overall, the Westinghouse SE 6000 represents a modern solution in the realm of power management systems. By leveraging cutting-edge technologies, it provides utilities with the tools necessary to enhance operational efficiency, increase safety, and embrace the transition toward sustainable energy practices. Its combination of robust features, user-friendly design, and adaptability makes it a leading choice in power system management.