C-4

APPENDIX C: SYSTEM TRANSACTIONS — NUMERICAL SEQUENCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

Message

Explanation

 

 

 

 

 

 

 

83

Enter Unattended Mode

Optional parking function.

 

84

Batch Request Received

Not used at this time.

 

 

 

 

 

 

85

Remote Comm Ended

Not used at this time.

 

86

Global Silence Request

Silence global beeping command issued.

 

 

 

 

 

 

89

Ticket Serviced

Parking application has completed ticket update/storage activities.

 

90

Chksum Err In Sys DB

Difference exists between host and ACU system data.

 

 

 

 

 

 

91

Chksum Err In Key DB

Difference exists between host and ACU key data.

 

92

Alarm Active

Alarm input active.

 

 

 

 

 

 

93

Alarm Clear

Previously active alarm input cleared.

 

94

Shunt Point

Device / point shunt command issued.

 

 

 

 

 

 

95

Unshunt Point

Device / point unshunt command issued.

 

96

Not Used

Reserved for future applications.

 

 

 

 

 

 

97

Parameter Load Error

Host poller initialization failed.

 

98

Tran File Almost Full

Archive history file approaching capacity. Archive immediately.

 

 

 

 

 

 

99

Database Error

Data to database failed. There may be many possible causes.

 

100

Passback Violation

Access denied — passback status.

 

 

 

 

 

 

103

Building Open

808-series — ACU in open mode.

 

104

Building Open Limited

808-series

ACU in limited mode.

 

 

 

 

 

 

 

105

Building Closed

808-series

ACU in closed mode.

 

106Tamper Report Shunted 8xx-series ACUs — device tamper report is shunted.

107Tamper Report Unshunt 8xx-series ACUs — device tamper report is unshunted.

108

Request To Exit

REX contact activated during valid REX time.

 

 

 

 

 

 

109

REX Denied

REX contact activated during invalid REX time.

 

110

MSM Fail

MSM failed.

 

 

 

 

 

 

111

MSM Okay

Previously failed MSM repaired.

 

112

Door Report Shunted

Door forced report shunted.

 

 

 

 

 

 

113

Door Report Unshunted

Door forced report unshunted.

 

114

Power Report Shunted

Device power fail report shunted.

 

 

 

 

 

 

Page 161
Image 161
Westinghouse SE 6000 manual Appendix C System Transactions Numerical Sequence

SE 6000 specifications

The Westinghouse SE 6000 is an advanced digital power management system designed for comprehensive control over electrical grids and power generation facilities. Its versatility and reliability make it a favored choice among utility providers and energy managers. The SE 6000 is equipped with numerous features that enhance efficiency, safety, and operational oversight.

One of the standout features of the Westinghouse SE 6000 is its robust data analytics capability. The system employs state-of-the-art telemetry and monitoring technologies that allow for real-time data collection and analysis. This enables operators to track power usage trends, identify inefficiencies, and make informed decisions regarding energy distribution and consumption.

Another key characteristic of the SE 6000 is its support for multiple communication protocols. This compatibility ensures seamless integration with existing infrastructure and facilitates interoperability among various devices and systems. Whether using DNP3, IEC 61850, or other industry-standard protocols, users can easily connect the SE 6000 to their grid management systems.

The SE 6000 features advanced protection mechanisms that are crucial for maintaining system integrity. Its built-in protection algorithms monitor for fault conditions and automatically execute pre-configured responses, thereby minimizing downtime and ensuring uninterrupted power delivery. This proactive approach to fault management helps safeguard both equipment and personnel.

In terms of user experience, the SE 6000 boasts an intuitive interface that simplifies the complexity of power management. The graphical user interface is designed with operator ergonomics in mind, offering customizable dashboards and clear visualizations of system performance metrics. This makes it easier for operators to monitor operations and respond quickly to potential issues.

Moreover, the SE 6000 is designed to support renewable energy systems, showcasing its adaptability to the evolving energy landscape. With the increasing integration of solar, wind, and other renewable sources, this platform is geared toward facilitating grid stability and reliability in conjunction with fluctuating power outputs.

Overall, the Westinghouse SE 6000 represents a modern solution in the realm of power management systems. By leveraging cutting-edge technologies, it provides utilities with the tools necessary to enhance operational efficiency, increase safety, and embrace the transition toward sustainable energy practices. Its combination of robust features, user-friendly design, and adaptability makes it a leading choice in power system management.