TROUBLESHOOTING

TROUBLESHOOTING

Note: All troubleshooting items are listed in order of operation.

OBSERVED PROBLEM WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

POSSIBLE CAUSE CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed,

1. Ignitor electrode not con-

1.

Reconnect ignitor cable

there is no spark at ODS/pilot

 

nected to ignitor cable

 

 

 

2.

Ignitor cable pinched or wet

2.

Free ignitor cable if pinched

 

 

 

 

by any metal or tubing. Keep

 

 

 

 

ignitor cable dry

 

3.

Piezo ignitor nut is loose

3.

Tighten nut holding piezo igni-

 

 

 

 

tor to base panel of log set. Nut

 

 

 

 

is located behind base panel

 

4.

Broken ignitor cable

4.

Replace ignitor cable

 

5.

Bad piezo ignitor

5.

Replace piezo ignitor

 

6.

Ignitor electrode broken

6.

Replace pilot assembly

 

7.

Ignitor electrode positioned wrong

7.

Replace pilot assembly

 

 

 

 

When ignitor button is pressed,

1. Gas supply turned off or equip-

1.

Turn on gas supply or open

there is spark at ODS/pilot but

 

ment shutoff valve closed

 

equipment shutoff valve

no ignition

2. Control knob not in PILOT

2.

Turn control knob to PILOT

 

 

position

 

position

 

3.

Control knob not pressed in

3.

Press in control knob while in

 

 

while in PILOT position

 

PILOT position

 

4.

Air in gas lines when installed

4.

Continue holding down con-

 

 

 

 

trol knob. Repeat igniting op-

 

 

 

 

eration until air is removed

 

5.

Depleted gas supply (propane/

5.

Contact local propane/LP gas

 

 

LP only)

 

company

 

6.

ODS/pilot is clogged

6.

Clean ODS/pilot (see Clean-

 

 

 

 

ing and Maintenance, pages

 

 

 

 

24 and 25) or replace ODS/

 

 

 

 

pilot assembly

 

7.

Gas regulator setting is not correct

7.

Replace gas regulator

 

 

 

 

ODS/pilot lights but flame goes

1. Control knob not fully pressed in

1.

Press in control knob fully

out when control knob is re-

2.

Control knob not pressed in

2.

After ODS/pilot lights, keep con-

leased

 

long enough

 

trol knob pressed in 30 seconds

 

3.

Equipment shutoff valve not

3.

Fully open equipment shutoff

 

 

fully open

 

valve

 

4.

Pilot flame not touching ther-

4.

A) Contact local propane/LP

 

 

mocouple, which allows ther-

 

or natural gas company

 

 

mocouple to cool, causing pi-

 

 

 

 

lot flame to go out. This prob-

 

B) Clean ODS/pilot (see

 

 

lem could be caused by one or

 

Cleaning and Maintenance,

 

 

both of the following:

 

pages 24 and 25) or replace

 

 

A) Low gas pressure

 

ODS/pilot assembly

 

 

B) Dirty or partially clogged

 

 

 

 

ODS/pilot

 

 

 

5.

Thermocouple connection

5.

Hand tighten until snug, then

 

 

loose at control valve

 

tighten 1/4 turn more

 

6.

Thermocouple damaged

6.

Replace pilot assembly

 

7.

Control valve damaged

7.

Replace control valve