Desa CRL2718P/N, CRL3124P/N Pilot Flame Pattern, Burner Primary Air Holes, Main Burner

Models: CGD3924PT/NT CGD3018PT/NT CRL3124P/N CRL2718P/N

1 44
Download 44 pages 38.64 Kb
Page 24
Image 24
PILOT FLAME PATTERN

INSPECTING BURNERS

Check pilot flame pattern and burner flame pat- terns often.

PILOT FLAME PATTERN

Figure 39 shows a correct pilot flame pattern. Figure 40 shows an incorrect pilot flame pattern. The incor- rect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 40

turn heater off (see To Turn Off Gas to Appli- ance, page 21 [manually-controlled models] or page 23 [thermostat-controlled models])

see Troubleshooting, pages 26 through 28 Note: The pilot flame on natural gas units will have a slight curve, but flame should be blue and have no yellow or orange color.

Pilot Burner

Thermocouple

Figure 39 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

Figure 40 - Incorrect Pilot Flame Pattern

BURNER PRIMARY AIR HOLES

Air is drawn into the burner through the holes in the fitting at the entrance to the burner. These holes may become blocked with dust, lint, or pet hair. Periodi- cally inspect these holes for any blockage and clean as necessary. Blocked air holes will create soot.

MAIN BURNER

Periodically inspect all burner flame holes with the heater running.All slotted burner flame holes should be open with yellow flame present.All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Remove blockage. Blocked burner flame holes will create soot.

CLEANING AND

MAINTENANCE

Figure 39 - Correct Pilot Flame Pattern WARNING: Turn off heater and let cool before cleaning.

BURNER PRIMARY AIR HOLES CAUTION: You must keep control areas, burner, and cir- culating air passageways of heater clean. Inspect these ar- eas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding mate- rial, pet hair, etc.

MAIN BURNER WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage.

BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater in- spected yearly by a qualified service person.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using com- pressed air no greater than 30 PSI. Your local com- puter store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 41, page 25).

24

www.desatech.com

111160-01C

Page 24
Image 24
Desa CRL2718P/N, CRL3124P/N, CGD3018PT/NT Burner Primary Air Holes, Main Burner, Correct Pilot Flame Pattern