Desa CGD3924PT/NT Continued, To Turn Off Gas To Appliance, Thermostat Control Operation, Pilot

Models: CGD3924PT/NT CGD3018PT/NT CRL3124P/N CRL2718P/N

1 44
Download 44 pages 38.64 Kb
Page 23
Image 23
THERMOSTAT

OPERATING HEATER

Continued

5.Turn control knob counterclockwiseFigure 37 - Control Knob and Ignitor to the PILOT position. Press in control knob for five (5) seconds (see Figure 37).

Note: You may be running this heater for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

If control knob does not pop out when re- leased, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, press and re- lease ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

7.Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety inter- lock system. Wait one (1) minute for sys- tem to reset before lighting pilot again.

8.Turn control knob counterclockwise

Button Location to desired heating level. The burn- ers should light. Set control knob to any heat level between HI and LO.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

Turn control knob clockwise Figure 38 - Pilot to the OFF position.

Shutting Off Burners Only (pilot stays lit)

Turn control knob clockwise Manual background to the PI- LOT position.

THERMOSTAT

CONTROL OPERATION

The thermostat control knob can be set to any comfort level between HI and LO. The ther- mostat will gradually modulate the heat out- put and flame height from higher to lower set- tings, or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

Note: Selecting the HI setting with the control knob will cause the burners to remain fully on, without modulating down in most cases.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Lighting In- structions, pages 22 and 23.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob. Now follow step 8, under Lighting Instructions, column 1.

OFF

Pilot

Ignitor Button

Control Knob

 

Figure 37 - Control Knob and Ignitor

 

Button Location

Ignitor

Pilot Burner

Electrode

Thermocouple

Figure 38 - Pilot

111160-01C

www.desatech.com

23

Page 23
Image 23