CLEANING AND

MAINTENANCE

Continued

3.Blow air through the ports/slots and holes in the burner.

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the in- jector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4 on page 24.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot as- sembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 42). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if com- pressed air is not available.

Burner Tube

Injector

 

Holder

Primary Air

Inlet Holes

Figure 41 - Injector Holder On Outlet

Burner Tube

Ports/Slots

Burner Tube Figure 42 - Pilot Inlet Air Hole

Pilot Assembly LOGSManual backgroundManual backgroundManual background

Pilot Air

Inlet Hole

Figure 42 - Pilot Inlet Air Hole

LOGS

If you remove logs for cleaning, refer to In- stalling Logs, pages 16 through 19, to properly replace logs.

Replace log(s) if broken or chipped (dime-sized or larger).

MAIN BURNER

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Remove blockage. Blocked burner flame holes will create soot.

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

for propane/LP units, propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, contact your local propane/LP or natural gas sup- plier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Heating Products’ Technical Service Department at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready.

You can also visit DESA Heating Products’ tech- nical service web site at www.desatech.com.

111160-01C

www.desatech.com

25

Page 25
Image 25
Desa CRL3124P/N, CRL2718P/N Continued, Logs, Main Burner, Injector Holder On Outlet Burner Tube, Pilot Inlet Air Hole