Desa CRL2718P/N, CRL3124P/N, CGD3018PT/NT WARNING: If you smell gas •Shut off gas supply

Models: CGD3924PT/NT CGD3018PT/NT CRL3124P/N CRL2718P/N

1 44
Download 44 pages 38.64 Kb
Page 28
Image 28
 WARNING: If you smell gas

TROUBLESHOOTING

Continued

Manual background WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM POSSIBLE CAUSE

REMEDY

Heater produces unwanted 1.

Heater burning vapors from

odors

paint, hair spray, glues, cleaners,

 

chemicals, new carpet, etc. (See

 

IMPORTANT statement above)

2.

Gas leak. See Warning

 

statement above

1.Open window and ventilate room. Stop using odor caus- ing products while heater is running

2.Locate and correct all leaks (see Checking Gas Connec- tions, pages 14 and 15)

Heater shuts off in use

1.

Not enough fresh air is available

1.

Open window and/or door for

(ODS operates) temperature

 

 

 

ventilation

drops to a lower than ideal level

2.

Low line pressure

2.

Contact local propane/LP or

before log set comes back on

 

 

 

natural gas company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Clean-

 

 

 

 

ing and Maintenance, pages

 

 

 

 

24 and 25)

 

 

 

 

 

Gas odor even when control

1.

Gas leak. See Warning

1.

Locate and correct all leaks

knob is in OFF position

 

statement above

 

(see Checking Gas Connec-

 

 

 

 

tions, pages 14 and 15)

 

2.

Control valve defective

2.

Replace control valve

Gas odor during combustion

1.

Foreign matter between con-

 

 

trol valve and burner

 

2.

Gas leak. See Warning

 

 

statement above

1.Take apart gas tubing and re- move foreign matter

2.Locate and correct all leaks (see Checking Gas Connec- tions, pages 14 and 15)

Logs set cycles to pilot, but room 1. Thermostat sensing bulb needs to be repositioned

1.Reposition thermostat sensing bulb (see Optional Positioning of Thermostat Sensing Bulb, beginning on page 29

28