ElectricalRequirements
Electrical requirements are different for the two models pictured on the cover, depending on the ampere rating of your unit. The number of amperes is printed on the serial plate, which is attached to the front of the unit behind the front panel (see diagram on page 12).
Observe all local governing codes and ordinances.
Do not, under any circumstances, remove the power supply cord grounding prong.
Receptaclewiring
Receptacle wiring should be a minimum of 14 gauge. Use copper wire only. It is the personal responsibility of the consumer to provide proper and adequate receptacle wiring installed by a qualified electrician. Observe National Electrical Code and all local governing codes and ordinances.
Z&prong
Electricalrequirements
Electrical Shock Hazard
l Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded. Do not modify the power supply cord plug - if it will not fit the outlet, have a proper outlet installed
by a qualified electrician. Improper connection of the
l Do not use an extension cord with this appliance. Such use may result in a fire, electrical shock or other personal injury.
. Do not have a fuse in the neutral or grounding circuit. This could result in a
risk of electrical shock.
A 115 volt, 60 Hz AC only, 15 ampere fused elec- trical supply is required (time delay fuse or time delay circuit breaker required). It is recommended that a separate circuit, serving only this appliance, be provided for models with serial plate amperes up through 7.5. A separate circuit is required
for models with serial plate amperes of 7.6 through 12.0.
Electricalconnection
Electrical ground is required on this appliance.
Recommended grounding method
For your personal safety, this appliance must be grounded. This air conditioner is equipped with a power supply cord having a
3