Troubleshooting
AUTOMATIC ELECTRONIC DIAGNOSTICS
This water softener has a
FIG. 82
A service person should be contacted to perform the diagnostics, see below, to further isolate the problem. Procedure for removing error code from dis- play:
1. Unplug transformer from electrical outlet.
2. Correct problem.
3. Plug in transformer.
4. Wait 6 minutes. The error code will return if the problem was not corrected.
CHECKING THE TURBINE
Use the following procedure to check the turbine that measures water flow through the softener.
1. Press the INFO button on the softener’s status screen to display the Water flow screen (See Figure 83).
FIG. 83
2. Open a nearby soft water faucet. There should be a
3.When water is flowing, the Water used today screen (See Fig. 84) can be used to check the tur- bine reading against volume of water exiting the softener. Beginning when this screen is displayed, a beep sounds with each gallon (or liter, as set).
FIG. 84
OTHER INITIAL DIAGNOSTICS
NOTE: Be sure water is in contact with the salt, and not separated by a salt bridge (See "Breaking A Salt Bridge" section).
Other information which may be beneficial in diagnos- ing problems may be found in the Total recharges and Days in use information screens. This informa- tion is retained by the computer from the first time electrical power is applied to the electronic controller. On the softener’s status screen, press the INFO but- ton, then the LEFT ( ) button to display these screens (See Page 12).
CHECKING THE MODEL CODE
1. Unplug the softener’s transformer and plug it back in, watching the touch screen display.
2. After the
E-Z Touch
FIG. 85
FIG. 86
3. The correct code for Model WHES48 is “EZ 48.” This code identifies the softener model. If an incor- rect model code is displayed, the softener will oper- ate on incorrect configuration data.
24