M1102/M1103 16-Speed Drill Press

ELECTRICAL

110V Operation

The SHOP FOX® Model M1102/M1103 operates at 110 volts and draws 8.5 amps. Use a NEMA-style 5-15 plug and receptacle (Figure 1) to connect your machine to power.

We recommend connecting this machine to a dedicated circuit with a verified ground, using a 15 amp circuit breaker. Never replace a circuit breaker with one of higher amperage without consulting a qualified electri- cian to ensure compliance with wiring codes. Otherwise you may overload the wire and plugs in the circuit.

If you are unsure about the wiring codes in your area or you plan to connect your machine to a shared cir- cuit, you may create a fire hazard—consult a qualified electrician to reduce this risk.

Extension Cords

We do not recommend using an extension cord for equip- ment. Instead, arrange the placement of your machinery and installed wiring to eliminate the need for extension cords. If you must use an extension cord, please use the following guidelines:

Use cords rated for Standard Service

Never exceed a length of 50 feet

Use cords with 14 ga. wire or bigger

Ensure cord has a ground wire and pin

Do not use cords in need of repair

Figure 1. Typical 110V 15A 3-prong plug

and outlet.

This equipment must be grounded. Verify that any existing electrical out- let and circuit you intend to plug into is actually grounded. If it is not, it will be necessary to run a separate 12 AWG copper grounding wire from the outlet to a known ground. Under no circum- stances should the grounding pin be removed from any three-pronged plug or serious injury may occur.

ELECTRICAL

Grounding

This machine must be grounded! If your power supply receptacle does not accommodate a ground pin, have the receptacle replaced by a qualified electrician or have an appropriate adapter installed and grounded properly. An adapter with a grounding wire does not guarantee the machine will be grounded. A ground source must be veri- fied.

-9-

Page 11
Image 11
Woodstock M1102, M1103 owner manual Electrical, 110V Operation, Extension Cords, Grounding