W1752 Owner's Manual (Mfg. 1/07+)

ELECTRICAL

110V Operation

ELECTRICAL

The Model W1752 is wired for 110V operation. Always con- nect this machine to a dedicated circuit (wire, breaker, plug, receptacle) with a verified ground, using the recom- mended circuit size and plugs/receptacles listed at the bottom of this page.

We recommend connecting this machine to a dedicated circuit with a verified ground, using the circuit size given below. Never replace a circuit breaker with one of higher amperage without consulting a qualified electrician to ensure compliance with wiring codes.

This machine must be grounded! The electrical cord sup- plied with this machine comes with a grounding pin. If your outlet does not accommodate a ground pin, have it replaced by a qualified electrician.

If you are unsure about the wiring codes in your area or you plan to connect your machine to a shared cir- cuit, you may create a fire or circuit overload hazard— consult a qualified electrician to reduce this risk.

Extension Cords

We do not recommend using an extension cord; however, if you have no alternative, use the following guidelines:

Use a cord rated for Standard Service (S).

Do not use a cord longer than 50 feet.

Ensure that the cord has a ground wire and pin.

Use the gauge size listed below as a minimum.

Figure 2. 5-15 plug and receptacle.

DO NOT work on your electrical system if you are unsure about electrical codes and wiring! Seek assistance from a qualified electrician. Ignoring this warning can cause electrocution, fire, or machine damage.

Electrical Specifications

Operating Voltage

Amp Draw

Min. Circuit Size

Plug/Receptacle

Extension Cord

110V Operation

6 Amps

15A

NEMA 5-15

14 Gauge

-10-