Worth Data 7000 manual System Tools, Characters, Download File, Play Voice Prompt

Models: 7000

1 95
Download 95 pages 40.52 Kb
Page 26
Image 26

Characters

This setting allows the RF Terminal to output chosen ASCII characters in place of the actual characters entered. For example, if you scanned the number 1 (hex 31) and wanted the RF Terminal to output hex 92 instead, you would enter 3192 for the Characters parameter. This would re-assign the output characters, with the RF Terminal outputting hex 92 every time it sees hex 31. To re-assign characters:

Select option “8” from the RF Terminal Setup menu then “3” to enable character entry. A square cursor will appear.

Enter up to seven 4-digit pairings where the first 2 digits represent the hex number to replace and the second 2 digits represent the hex number to insert. You can have up to seven character reassignments.

Press “Enter” when done or “Clear” to reset to none.

You can eliminate the output of a character by using FF as the hex number to insert. For example, if you wanted to eliminate all $, following the above instructions, enter 24FF.

System Tools

Download File

This will allow you to download a new voice prompt file or a firmware update. You must run the utility program on the PC to download the file.

Play Voice Prompt

To play a voice prompt, select option “2” then enter the 2-digit number of the voice prompt that you wish to play. The valid range is 01 to 99.

Reset to Factory Default

Select option “3” to reset all setup values to the factory default values. This will reset all values in all menus of the RF TERMINAL SETUP.