The cable between the Base Station and host computer is bad. Try the test with extension cables removed.

The host COM port is bad or assigned to another device driver installed. Try another COM port or try another computer.

RARELY!!! The RS232 chip on the Base Station is bad.

Terminal Error Messages

Message

Relay n Cannot be

Heard by the Base

Notify Supervisor

Transmission Failed To

Retry, Move Closer And

Press Enter

One Way Not Allowed

Base in Other Mode

Press <Enter> Key

Site Testing Not

Allowed, Base in Other

Mode Press <Enter>

Key

No Firmware Detected

1 – Download Firmware

0 – Power off Terminal Press 0 or 1 now_

Duplicated Terminal ID, Notify Supervisor Press Any Key to Turn off Terminal

RED LED

GREEN LED

YELLOW LED

Meaning – Action Required

The terminal has established contact with Relay Station x. Relay Station x has attempted to communicate with the Base Station through the 422 cabling with no success. Cable is bad.

The terminal has tried 10 times to get its message through to the Base Station with no success. Could be result of bad radio in base or terminal. Could be the operator has gone out of range of the base- if so, move closer and press any key. Could also be that there are too many terminals competing for radio time on one base station.

One-Way is not allowed if the Base is already in some other mode such as Two-Way or Site Testing which was not properly concluded. Also, if you are SIGNed IN in One-Way mode and someone else SIGNs IN in Two-Way mode, the person in One-Way mode will be kicked out of the system with this message. Two-Way mode ALWAYS supercedes all other modes.

Site Testing is not allowed if the Base is already in some other mode such as Two-Way or One-Way which was not properly concluded. Also, Two-Way mode ALWAYS supercedes other modes. If you are Site Testing and someone SIGNs IN in Two-Way mode, you will be kicked out of the system with this error message.

The firmware has somehow been wiped out – probably from an interrupted firmware download. Press 1 to Download Firmware or press 0 to power off the terminal.

With one ID already SIGNed IN to the host, a second terminal with the same ID tried to SIGN IN. Every terminal requires a unique ID for proper system operation.

The Pick processor cannot communicate. Call for RMA.

Base operating as a Base (default configuration)

Base operating as a Relay

Message

Meaning – Action Required

“Waiting for Base to

This is a normal message, generated when you

Acknowledge...?

first establish radio contact. If you continue to get

 

this message and it results in a "Transmission

 

Failed" message, your Radios in Base and

 

Terminal are not communicating. Be sure they are

 

on same channel. They may need repair.

Waiting on Host

Problem is between Host computer and Base

Prompt

station. Check to see if host application is

 

running. Check serial parameters and eliminate

 

any extension cables. Run the Demo program. Try

 

another COM port or another computer.

 

Problem is in host program. Notify programmer!

“Base Station Shut

If the Base Station receives 5 Sequence Errors in

Down Due to Host

a row, it transmits the message to all terminals

Logic Error, Cycle

signed in and shuts down. Check your host

Terminal Power”

program for the sequence error before starting up

 

again. OR

 

If the Base Station receives 5 messages

 

addressed to a Terminal not Signed ON, it

 

transmits this message to the all terminals signed

 

in and shuts down.

 

You will have to cycle power on the Base Station

 

or you can send a command (*@EOT) form the

 

host and have the Terminal Sign On again to

 

continue. See Chapter 6, page 6-8 for more

 

information on Sequence Errors.

Base Reinitialized X Base Station has been reinitialized. If message Cycle Power on RF reads “Base Reinitialized P”, then reinitialization is Terminal and Sign-ondue to a power problem. If “Base Reinitialized H”

again to Restart_” then the reinitialization was initiated by the host

program. Fix problem (cycle power on Base or re- initialize from host program).

Buffer Reinitialized The host program has reinitialized the buffer in the Cycle Power on RF Base Station for this terminal only. The Base is still Terminal and Sign-onoperational and ready for you to power off your

again to Restart_” terminal, power on, and SIGN ON again. Other

terminals are not affected.

LOW BATTERY Finish,

Finish the transaction you have started. The Press

Sign Off Charge

F1 to Sign Out. Then turn off the Terminal and

Battery

charge the battery. This is an early warning that

 

the battery is getting low and should be charged

 

soon.

CHARGE BATTERY

The terminal will display this message for 20

UNIT SHUT DOWN

seconds, sign out, and turn off.

 

The unit will not operate until the battery is

 

charged.

Page 70
Image 70
Worth Data 7000 manual Terminal Error Messages, Message Meaning Action Required

7000 specifications

The Worth Data 7000 is an advanced data collection and management device designed for various applications, including inventory control, asset tracking, and point-of-sale transactions. This versatile handheld device excels in environments requiring efficiency and reliability, making it a popular choice for businesses looking to optimize their operational workflows.

One of the standout features of the Worth Data 7000 is its robust barcode scanning capabilities. Equipped with a high-quality scanner, it can read a wide range of barcode formats, including 1D and 2D barcodes. This versatility ensures that users can seamlessly integrate the device into existing systems and easily manage different types of inventory, thereby reducing errors and improving data collection accuracy.

The Worth Data 7000 leverages advanced wireless technology, including Bluetooth and Wi-Fi connectivity, allowing for real-time data transfer to cloud-based systems or local servers. This capability is crucial for businesses that require instantaneous updates and access to critical information across multiple locations. The device is also compatible with various mobile applications, enhancing its functionality and enabling users to perform transactions and updates remotely.

In terms of hardware, the Worth Data 7000 features a durable design that meets the demands of industrial and retail environments. Its rugged casing is designed to withstand drops, impacts, and exposure to dust and moisture, ensuring longevity and reliability in challenging conditions. The device is also equipped with an intuitive touchscreen interface, making it user-friendly and accessible, even for those with minimal technical skills.

Another important characteristic of the Worth Data 7000 is its long-lasting battery life. Designed for extended use, the device can operate for hours on a single charge, allowing employees to focus on their tasks without frequent interruptions for recharging. This is particularly beneficial in fast-paced environments where time is of the essence.

Furthermore, the Worth Data 7000 supports a variety of software applications that can be tailored to meet specific business needs. From inventory management systems to customized point-of-sale solutions, the device offers flexibility and scalability for businesses of all sizes.

In conclusion, the Worth Data 7000 stands out as a powerful tool for data collection and management, thanks to its superior barcode scanning capabilities, robust connectivity options, durable design, extended battery life, and flexibility in software applications. Whether for retail, warehouse management, or asset tracking, it is a reliable choice for businesses looking to enhance their operational efficiency and improve data accuracy.