Configuration

 

In power systems with long cables between the batteries and the inverter/

 

charger (over 10 feet [3 m]), the measured battery voltage can be a poor

 

indicator of battery condition. In such cases, the batteries are more

 

assured of a full charge if the generator runs until the charger reaches the

 

Absorb stage, rather than waiting until the charger charges the batteries to

 

the voltage you may have set for “StopBattV” (see page 3–22).

 

For more information on battery charging, see your inverter/charger

 

operation guide.

Outcomes

If you enable the Auto Gen Start to stop the generator at the Absorption

 

stage, it will stop the generator if it has been started automatically by the

 

Battery Voltage (“StartV:30sec”, “StartV:15min”, “StartV:2hr”, and

 

“StartV:24hr”) or State of Charge settings.

 

If you do not set “Stop Absorb” to On, the Auto Gen Start will not stop

 

the generator in response to the battery charging stage. The generator will

 

stop in response to battery voltage (“StopBattV”) instead. In this case,

 

ensure that the “StopBattV” is enabled and set at the correct voltage.

Stop Float

Full name

Stop at Float Charge Stage

Purpose

The “Stop Float” setting allows you to set the Auto Gen Start to stop the

 

generator when the inverter/charger has recharged the batteries to the

 

Float stage.

 

 

 

Values

 

Default

 

 

 

 

 

 

 

Off, On

 

Off

 

 

 

 

When to use

Set “Stop Float” if your inverter/charger is using three-stage battery

 

charging.

 

 

Set “Stop Float” to On if battery charging is your main priority for your generator (rather than using your generator for powering high AC loads). You might also use the “Stop Float” setting if your batteries are not being charged enough before the Auto Gen Start stops the generator because of battery voltage or state of charge.

In power systems with long cables between the batteries and the inverter/ charger (over 10 feet [3 m]), the measured battery voltage can be a poor indicator of battery condition. In such cases, the batteries are more

3–26

975-0082-01-01

Page 74
Image 74
Xantrex Technology Automatic Generator manual Stop Float

Automatic Generator specifications

Xantrex Technology has established a reputation for excellence in the power management sector, and its Automatic Generator Start (AGS) system is a prime example of this commitment to innovation. This advanced technology is designed for use in recreational vehicles (RVs), marine applications, and remote cabins, providing a reliable solution for maintaining power during off-grid conditions.

One of the main features of the Xantrex AGS is its ability to automatically start and stop generator engines based on specific parameters set by the user. This ensures that power is available when needed, while also preserving fuel and extending the life of the generator itself. The AGS monitors the battery voltage closely, activating the generator if it drops below a predetermined threshold. Once the battery is adequately charged, the system will automatically shut the generator off, preventing unnecessary fuel consumption and wear on the engine.

The Xantrex AGS operates using a sophisticated microprocessor that allows for precise control and adaptability. This technology enables users to customize various settings according to their power needs, ensuring optimal efficiency. Users can also configure the system to respond to temperature or water level conditions, tailoring the performance to specific environments and requirements.

In addition to its automatic functionality, the Xantrex AGS is designed with user-friendliness in mind. A clear, intuitive interface allows for easy setup and adjustments, ensuring that anyone can operate the system effectively. This is particularly advantageous for users who may not be technically inclined or those who are new to generator technology.

Moreover, the system is equipped with advanced safety features that protect both the generator and the connected devices from potential damage. This includes overload protection and additional protocols that prevent the generator from starting during unsafe conditions, providing peace of mind to users.

Overall, the Xantrex Technology Automatic Generator Start system exemplifies a blend of innovation, practicality, and safety features. With its ability to manage power effectively while reducing operational costs, it is an indispensable tool for anyone who relies on a generator for off-grid power supply. Whether for adventures in an RV, tasks on a boat, or maintaining remote properties, the Xantrex AGS stands out as a top choice for reliable automatic generator management.