Configuration

 

Use the Quiet Time feature to ensure that the generator will not run during

 

the night, or to comply with “Quiet Time” guidelines at RV parks and

 

campgrounds.

 

To use the Auto Gen Start Quiet Time feature, first set “QT Enable” to

 

On, then set two times of the day or night (a Quiet Time Begin time and a

 

Quiet Time End time) to define a time interval during which the generator

 

will not run.

 

To disable the Quiet Time feature, set “QT Enable” to Off.

Time zone

When travelling between time zones, ensure that you set the clock on the

 

System Control Panel to your correct local time. Otherwise, your quiet

 

time settings will come into effect too early or too late.

Battery drain

Quiet Time prevents the automatic starting of the generator regardless of

 

battery condition.

 

If you need to set a quiet time that lasts overnight, be aware that overnight

 

battery drain can be significant. Because you may need to use an inverter

 

and batteries to supply AC power during quiet time, be careful to

 

conserve battery power. Minimize the use of interior lights and set

 

thermostat temperature lower to prevent the furnace from coming on at

 

night during cool weather. Set thermostats higher to prevent air

 

conditioning coming on at night during warm weather.

Outcomes

Sometimes automatic start or automatic stop triggers may overlap with

 

the beginning and end of quiet time. Three different quiet time scenarios

 

affect when the generator stops and starts.

 

1. If quiet time begins after the Auto Gen Start has started the generator,

 

the generator will stop. If the condition that started the generator is

 

still present when quiet time ends, the generator will restart.

 

2. If a condition that requires starting the generator occurs during quiet

 

time, the Auto Gen Start will ignore it until quiet time ends. If the

 

condition still exists at the end of quiet time (after the time you set for

 

“QT End”), the Auto Gen Start will start the generator.

 

3. If the running generator stops when quiet time begins and a condition

 

that requires stopping the generator occurs during quiet time, the

 

generator will not restart when quiet time ends.

3–12

975-0082-01-01

Page 60
Image 60
Xantrex Technology Automatic Generator manual Night, or to comply with Quiet Time guidelines at RV parks

Automatic Generator specifications

Xantrex Technology has established a reputation for excellence in the power management sector, and its Automatic Generator Start (AGS) system is a prime example of this commitment to innovation. This advanced technology is designed for use in recreational vehicles (RVs), marine applications, and remote cabins, providing a reliable solution for maintaining power during off-grid conditions.

One of the main features of the Xantrex AGS is its ability to automatically start and stop generator engines based on specific parameters set by the user. This ensures that power is available when needed, while also preserving fuel and extending the life of the generator itself. The AGS monitors the battery voltage closely, activating the generator if it drops below a predetermined threshold. Once the battery is adequately charged, the system will automatically shut the generator off, preventing unnecessary fuel consumption and wear on the engine.

The Xantrex AGS operates using a sophisticated microprocessor that allows for precise control and adaptability. This technology enables users to customize various settings according to their power needs, ensuring optimal efficiency. Users can also configure the system to respond to temperature or water level conditions, tailoring the performance to specific environments and requirements.

In addition to its automatic functionality, the Xantrex AGS is designed with user-friendliness in mind. A clear, intuitive interface allows for easy setup and adjustments, ensuring that anyone can operate the system effectively. This is particularly advantageous for users who may not be technically inclined or those who are new to generator technology.

Moreover, the system is equipped with advanced safety features that protect both the generator and the connected devices from potential damage. This includes overload protection and additional protocols that prevent the generator from starting during unsafe conditions, providing peace of mind to users.

Overall, the Xantrex Technology Automatic Generator Start system exemplifies a blend of innovation, practicality, and safety features. With its ability to manage power effectively while reducing operational costs, it is an indispensable tool for anyone who relies on a generator for off-grid power supply. Whether for adventures in an RV, tasks on a boat, or maintaining remote properties, the Xantrex AGS stands out as a top choice for reliable automatic generator management.