Configuring the Device Using DeviceInstaller

Figure 2-19Assigning IP Settings

9.In the IP Configuration section, click the radio button next to “Use the following IP configuration.”

Important: If you are working within a network system, please contact the network administrator for the appropriate information to complete the IP Address, Subnet Mask and Default Gateway fields

10.Click OK at the bottom of the page to complete the task.

11.Repeat this procedure for every power supply. Every device must have a unique fixed IP address.

Selecting ENET as the Communication Port

Once the XG unit with the ENET option has the option card configured, you’ll need to configure the XG to use the ENET option card as the active communication port.

To select ENET as the communication port:

1.Turn the 9-position Mode control to PGM. rE is displayed in the output voltage display.

M370078-06