Troubleshooting

Fault Code Descriptions

Table 4-1 provides a complete description of all the fault conditions that may occur on the PV225S.

Table 4-1Fault Codes

Error

 

Fault Type

 

 

 

 

H=Hardware

 

 

 

Code

Fault Source(s)

S=Software

Fault Description

Possible Causes

 

 

 

 

 

0000

No Faults

N/A

N/A

N/A

 

 

 

 

 

 

0010

AC Frequency Low

S

This fault indicates that the Utility

Utility grid frequency

 

 

 

grid frequency is below or fell below

 

fell below the allowable

 

 

 

the minimum allowed value of

 

limit

 

 

 

59.3 Hz for greater than 6 cycles.

 

 

 

 

 

This fault is auto-clearing. Once the

 

 

 

 

 

Utility grid frequency has recovered

 

 

 

 

 

within the acceptable operating

 

 

 

 

 

range, the PV225S will qualify the

 

 

 

 

 

value and automatically clear this

 

 

 

 

 

fault and resume normal operation

 

 

 

 

 

after 5 minute delay period.

 

 

 

 

 

 

 

 

0011

AC Frequency High

S

This fault indicates that the Utility

Utility grid frequency

 

 

 

grid frequency is above or rose above

 

rose above the

 

 

 

the maximum allowed value of

 

allowable limit

 

 

 

60.5Hz for greater than 6 cycles. This

 

 

 

 

 

fault is auto-clearing. Once the Utility

 

 

 

 

 

grid frequency has recovered within

 

 

 

 

 

the acceptable operating range, the

 

 

 

 

 

PV225S will qualify the value and

 

 

 

 

 

automatically clear this fault and

 

 

 

 

 

resume normal operation after

 

 

 

 

 

5 minute delay period.

 

 

 

 

 

 

 

 

0012

AC Voltage Low

S

This fault indicates that the utility

Utility grid voltage fell

 

 

 

grid voltage is below or fell below the

 

below the allowable

 

 

 

minimum allowed value of 88% of

 

limit

 

 

 

nominal Vac for greater than

• Fuses F1, F2, F3, F7, F8

 

 

 

2 seconds, or 50% of nominal VAC

 

or F9 blown

 

 

 

for greater than 6 cycles. This fault is

• P1001 on CCU2 is

 

 

 

auto-clearing. Once the Utility grid

 

loose or disconnected

 

 

 

voltage has recovered within the

 

 

 

 

 

acceptable operating range, the

 

 

 

 

 

PV225S will qualify the value and

 

 

 

 

 

automatically clear this fault and

 

 

 

 

 

resume normal operation after

 

 

 

 

 

5 minute delay period.

 

 

 

 

 

 

 

 

4–4

152607

Page 92
Image 92
Xantrex Technology PV225S-480-P manual Fault Code Descriptions, 1Fault Codes

PV225S-480-P specifications

The Xantrex Technology PV225S-480-P is a state-of-the-art power conversion solution designed to meet the needs of solar energy systems. As the demand for renewable energy sources continues to rise, the importance of efficient inverters becomes paramount. This model stands out for its high performance, reliability, and advanced features tailored for both residential and commercial applications.

One of the main features of the PV225S-480-P is its impressive power handling capability, capable of supporting peak loads up to 225 kW. This makes it ideal for large-scale solar installations, ensuring that energy generation meets or exceeds expected outputs. Additionally, the inverter operates at a high efficiency rate, typically exceeding 98%, which minimizes energy losses during conversion and maximizes the overall performance of the solar power system.

The PV225S-480-P utilizes advanced inverter technology that incorporates an innovative digital signal processor. This technology enhances the unit’s ability to track the maximum power point (MPPT) effectively, optimizing energy harvest even under varying sunlight conditions. The ability to adapt to different environmental factors ensures that the system consistently delivers optimal performance throughout the day.

Reliability and durability are crucial characteristics of the PV225S-480-P. Designed with robust materials and rigorous engineering practices, the inverter is built to withstand demanding conditions, including extreme temperatures and potential environmental hazards. Its sturdy design minimizes maintenance requirements, leading to lower operational costs over the inverter's lifespan.

The inverter is also equipped with comprehensive monitoring and communication capabilities. Users can easily access real-time performance data, allowing for proactive maintenance and immediate troubleshooting if issues arise. In addition, the unit supports integration with various energy management systems, enabling users to optimize their energy usage and reduce overall electricity costs.

Furthermore, the PV225S-480-P includes safety features that comply with international standards, ensuring protection against electrical faults and overvoltage. The inverter’s design incorporates fail-safe mechanisms to protect both the unit itself and connected equipment.

In summary, the Xantrex Technology PV225S-480-P is a highly efficient, reliable, and technologically advanced solar inverter. With its strong power handling capabilities, cutting-edge features, durability, and safety aspects, it is an excellent choice for anyone looking to invest in renewable energy solutions that provide long-term savings and environmental benefits.