43 (49) — Word length (data bits)
The serial port word length may be set for 5, 6, 7 or 8 bits. The default is 8 bits. Use the following values to program this option:
!ALLY!43=05; | 5 bit word length |
!ALLY!43=06; | 6 bit word length |
!ALLY!43=07; | 7 bit word length |
!ALLY!43=08; | 8 bit word length (default) |
44 (4A) — Stop bits
The default number of stop bits for the serial ports is 1. To program this option:
!ALLY!44=00; | no stop bits |
!ALLY!44=01; | one stop bit (default) |
45 (4B) — Flow control (handshaking)
There are two selections for flow control. The ALLY PLUS uses hardware handshaking by default. This option may be programmed as follows:
!ALLY!45=01; XON/XOFF (software) handshaking
!ALLY!45=02; RTS/CTS (hardware) handshaking (default)