170 Chapter 15Other Functions
D24—Owner’s Manual
Setting the Peak Hold Mode
Peak Hold can be set so that the highest lit segment of each meter remains lit for 800 ms
(MOMENTARY) or continuously (PERMANENT). See “Using Peak Hold” on page 41
for information on using the Peak Hold function.
1Press the [SETUP] button.
The SETUP indicator lights up.
2Use the JOG/DATA dial to select PEAK HOLD, and then press the [ENTER]
button.
The current setting appears on the display.
3Use the JOG/DATA dial to select MOMENTARY or PERMANENT.
The default setting is PERMANENT.
4Press the [ENTER] button to activate your selection, or the [CANCEL] button
to cancel the Peak Hold function.
5Press the [SETUP] button again to leave setup.
The SETUP indicator goes out.
Setting the Fade In/Out Time
When dissimilar sounds are digitally spliced together, the discontinuity and sudden
level change sometimes produces an audible click. To smooth the transition between
new and existing material at the punch-in and out points, and the part editing edit
points, a small fade in/out is applied, the length of which can be set to 2, 5, 10, 25, 50,
or 100 ms, the default being 2 ms.
1Press the [UTILITY] button.
The UTILITY indicator lights up.
2Use the JOG/DATA dial to select FADE I/O, and then press the [ENTER] but-
ton.
The currently set fade in/out time appears on the display.
3Use the JOG/DATA dial to select a fade in/out time: 2, 5, 10, 25, 50, or 100 ms.
The default setting is 2 ms.
4Press the [ENTER] button to activate your selection, or the [CANCEL] button
to cancel the Fade I/O function.
5Press the [UTILITY] button again to leave utility.
The UTILITY indicator goes out.
The Fade I/O setting can be changed at anytime and is applied to punch-in and out
points, and the part editing edit points during playback, not recording.