Problem

Cause

Remedy

Remote control does

The batteries are exhausted.

not work correctly.

 

The remote control sensor is not set

 

 

correctly.

 

 

 

There is a fluorescent lamp near the

 

remote control sensor being used.

 

 

 

The remote control code switch is

 

incorrectly set.

 

 

 

 

COVER warning

The filter cover is not correctly attached.

indicator lights up.

 

The lamp cover is not correctly attached.

 

 

 

 

 

LAMP warning

Lamp running time has exceeded 2000

indicator lights up or

hours.

blinks.

 

The lamp has burned out.

 

 

 

 

 

TEMP warning indicator

The temperature inside the DPX-1300 is

lights up.

extremely high.

 

 

 

 

FAN warning indicator

The fan is broken.

lights up.

 

 

 

Replace both batteries with new ones.

Set correctly.

Press the MENU button to display the menu

and select [Setup] [Remote Control Sensor].

Turn off the remote control sensor near the fluorecent lamp, and use the other remote sensor.

Set the remote control code switch to the same ID number as the setting on the “REMOTE CONTROL ID” in the setting menu.

Tightly attach the filter cover.

Tightly attach the lamp cover.

Replace the lamp with a new one.

Replace the lamp with a new one.

Check that the ventilation slots are not covered.

Contact the store where the DPX-1300 was purchased.

This unit uses a DMDTM chip for the picture display. Their highly accurate technology makes it possible to keep more than 99.99% of effective pixels, however, unexpectedly it can produce less than 0.01% of ineffective pixels. In such a case, missing or flashing of a few pixels can be found on the screen. These are characteristics of DMDTM , not mechanical problems.