Connecting the power cable

CONNECTIONS

Connecting the power cable

Once all connections are complete, plug the power cable into the AC wall outlet.

(U.S.A. model)

AC OUTLETS

To the AC wall outlet

CAUTION

VOLTAGE SELECTOR

(Asia and General models only)

The VOLTAGE SELECTOR on the rear panel of this unit must be set for your local voltage BEFORE plugging the power cable into the AC wall outlet. Improper setting of the VOLTAGE SELECTOR may cause damage to this unit and create a potential fire hazard.

Rotate the VOLTAGE SELECTOR clockwise or counterclockwise to the correct position using a straight slot screwdriver.

Voltages are as follows:

Asia model

220/230–240 V AC, 50/60 Hz

General model

110/120/220/230–240 V AC, 50/60 Hz

AC OUTLET(S) (SWITCHED)

 

U.K. and Australia models

1 outlet

Korea model

None

Other models

2 outlets

Use these outlet(s) to supply power to any connected components. Connect the power cable of your other components to these outlet(s). Power to these outlet(s) is supplied when this unit is turned on. However, power to these outlet(s) is cut off when this unit is in the standby mode or the power cable of this unit is disconnected from the AC wall outlet. For information on the maximum power or the total power consumption of the components that can be connected to these outlet(s), see “SPECIFICATIONS” on page 100.

Memory back-up

VOLTAGE

SELECTOR

230-

240V

Voltage indication

The memory back-up circuit prevents the stored data from being lost even if this unit is in the standby mode. However, the stored data will be lost in case the power cable is disconnected from the AC wall outlet or if the power supply is cut off for more than one week.