ENGINE FAILS TO OPERATEIf battery voltage is low or in the unlikely event of an ignition system malfunction, the engine speed may become erratic or the engine may stop. In such a case, disconnect the connection on the yellow cord (emergency circuit) to return to port.
w
When the connection is disconnected, the idling and low speeds are slightly higher than normal. Use care when starting off or stopping.
1CDI unit
2 Yellow cord
cC
Follow this procedure only in an emergency and just long enough to return to port for repairs.