2 | Press G | / | to select “AUTO SETUP” and |
| y | |
| then press GENTER. |
| • If “ENVIRONMENT CHECK [FAILED]” is displayed, | |||
|
| refer to “Error messages for AUTO SETUP” (page 18), | ||||
|
|
|
|
| ||
|
|
|
|
| press IRETURN, and then run the AUTO SETUP | |
|
|
| B)AUTO SETUP |
| procedure again. | |
|
|
|
| • If “SUBWOOFER :NOT APPLICABLE” is displayed | ||
|
|
|
|
| ||
|
| 1)BEAM+SOUND OPTIMZ |
| even though a subwoofer is connected to this unit and | ||
|
| 2)BEAM OPTIMZ ONLY |
| |||
|
|
| turned on, check the connection and then increase the | |||
|
| 3)SOUND OPTIMZ ONLY |
| |||
|
|
|
|
| volume level of the subwoofer and run the AUTO SETUP | |
|
|
|
|
| procedure again. | |
|
|
| [p]/[p]:Up/Down |
| • Depending on the environment of your listening room, the | |
|
|
| [ENTER]:Enter |
| beam angles of front right and left and surround left and | |
|
|
|
|
| ||
|
|
|
|
| right may be set to the same value even if “BEAM MODE | |
|
|
|
|
| :5 BEAM” is displayed as a result. | |
3 | Press G | / | to select “BEAM+SOUND | |||
|
| |||||
| OPTIMZ”, “BEAM OPTIMZ ONLY” or “SOUND |
|
| |||
| OPTIMZ ONLY” and then press GENTER. |
| 6 Press GENTER to confirm the results. | |||
|
|
|
|
| The menu screen disappears in two seconds. | |
|
|
| AUTO SETUP |
|
| |
|
| PREPARATION & CHECK |
|
| ||
| Please connect the MIC. |
|
| |||
| Please place the MIC at least |
|
| |||
| 1.8m/6ft away from the unit. |
| AUTO SETUP COMPLETE | |||
| The MIC should be set |
|
| |||
| at ear level when seated. |
| Please remove the MIC from | |||
| Measurement takes about 3min. |
| the unit and the listening | |||
| After [ENTER] is pressed, |
| position. | |||
| please leave the room. |
|
| |||
| [ENTER]:Start [RETURN]:Cancel |
|
| |||
|
|
| ||||
4 Prepare to leave the room. |
|
| ||||
| The best setting may not be done if you are in the |
| y | |||
| room. Prepare to leave the room in 10 seconds after |
| • If you do not want to reflect the results, press IRETURN. |
pressing GENTER in step 5.
7 Disconnect the IntelliBeam microphone.y
•Wait outside the room during the AUTO SETUP procedure.
•The AUTO SETUP procedure takes about 3 minutes.
•To cancel the AUTO SETUP procedure after it is started, press IRETURN.
5 Press GENTER to start the AUTO SETUP |
|
procedure and then leave the room within 10 |
|
seconds. | The measurement results are stored in the internal |
| |
AUTO SETUP START | memory of this unit until you run the AUTO SETUP |
procedure again or configure the settings manually. | |
Will begin in 10sec |
|
Please leave the room |
|
| |
[RETURN]:Cancel |
|
The setup screen automatically changes during the |
|
AUTO SETUP procedure. |
|
If an error occurs, an error buzzer sounds and an error |
|
message is displayed. For details on error messages, |
|
see “Error messages for AUTO SETUP” (page 18). |
|
If the AUTO SETUP procedure is complete, this unit |
|
rings the chimes. |
|
XXXXXXXXSHOW RESULTXXXXXXXXXX |
|
MEASUREMENT COMPLETE |
|
BEAM MODE :5Beam/Plus2 |
|
SUBWOOFER :YES |
|
[ENTER]:Save |
|
[RETURN]:Do not save |
|
Changing OSD
language
AUTO SETUP (IntelliBeam)
Using the system
memory
PREPARATION INTRODUCTION
FEATURES PLAYBACK
SETTINGS
APPENDIX