TABLE 5 – COOLING PERFORMANCE DATA – 65 TON MODEL (CONT’D)

FORM 100.50-EG1

TABLE 5 – COOLING PERFORMANCE DATA – 65 TON MODEL (CONT’D)

105° AIR ON CONDENSER COIL

 

 

 

 

 

 

 

 

CAPACITY (MBH) AT ENTERING DRY BULB (°F)

 

 

 

 

 

CFM

ENTERING

 

90

86

 

83

 

 

80

 

77

 

74

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WB (°F)

CAP

 

SHC

CAP

 

SHC

CAP

 

SHC

CAP

 

SHC

CAP

 

SHC

CAP

 

SHC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

 

780

 

560

777

 

493

774

 

442

771

 

393

768

 

342

 

14000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

67

 

737

 

646

717

 

581

714

 

529

714

 

476

711

 

430

708

 

381

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

62

 

710

 

710

682

 

682

650

 

621

658

 

565

655

 

516

653

 

466

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

 

792

 

591

788

 

516

785

 

461

781

 

406

777

 

351

 

18000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

67

 

753

 

683

730

 

613

726

 

556

725

 

499

721

 

447

718

 

393

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

62

 

732

 

732

703

 

703

672

 

650

669

 

595

666

 

542

663

 

486

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

 

812

 

643

805

 

555

802

 

493

798

 

429

794

 

365

 

21000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

67

 

771

 

746

752

 

668

746

 

604

744

 

538

738

 

476

734

 

413

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

62

 

771

 

771

739

 

739

711

 

700

689

 

647

685

 

586

681

 

522

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

 

831

 

696

822

 

595

820

 

524

816

 

452

810

 

379

 

24000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

67

 

809

 

809

774

 

722

766

 

651

762

 

576

756

 

505

751

 

433

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

62

 

809

 

809

774

 

774

750

 

750

709

 

698

704

 

630

699

 

558

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

 

840

 

720

830

 

613

828

 

539

823

 

462

817

 

386

 

27000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

67

 

826

 

826

784

 

747

775

 

673

770

 

594

763

 

518

759

 

442

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

62

 

826

 

826

791

 

791

767

 

772

718

 

721

712

 

650

707

 

574

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* Rated performance is at sea level. Cooling capacities are gross cooling capacity.

115° AIR ON CONDENSER COIL

 

 

 

 

 

CAPACITY (MBH) AT ENTERING DRY BULB (°F)

 

 

 

CFM

ENTERING

 

90

86

 

 

83

 

80

 

77

 

74

WB (°F)

CAP

SHC

CAP

SHC

CAP

SHC

CAP

SHC

CAP

SHC

CAP

SHC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

748

548

744

478

742

429

738

378

735

330

14000

67

708

639

690

570

686

517

684

463

681

417

678

368

 

62

681

681

664

664

621

608

625

550

628

503

625

452

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

759

578

754

502

752

448

748

392

744

338

18000

67

724

671

700

599

696

544

694

486

690

434

687

380

 

62

704

704

679

679

644

634

642

583

638

528

635

473

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

776

629

771

543

768

479

766

415

759

352

21000

67

741

725

716

650

714

591

711

523

706

462

703

400

 

62

741

741

706

706

682

678

669

640

655

571

651

508

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

794

680

789

584

784

511

784

438

774

366

24000

67

779

779

732

700

732

637

728

561

722

491

718

419

 

62

779

779

732

732

721

721

697

697

672

615

668

543

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

802

703

797

603

791

525

792

449

781

372

27000

67

796

796

740

723

740

658

736

578

729

504

725

428

 

62

796

796

740

717

738

648

710

563

680

490

676

414

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* Rated performance is at sea level. Cooling capacities are gross cooling capacity.