York THRU 060, B1HH018 230/460/575 volts, Side And Bottom Supply Air Blower Performance

Models: B1HH018 THRU 060

1 28
Download 28 pages 53.09 Kb
Page 12
Image 12

66297-YIM-C-0205

TABLE 20 - SIDE AND BOTTOM SUPPLY AIR BLOWER PERFORMANCE

230/460/575 volts

 

 

 

 

 

 

 

 

EXTERNAL STATIC PRESSURE - IWG

 

 

 

 

 

 

MODEL NO.

MOTOR

0.10

0.20

0.30

0.40

0.50

0.60

0.70

0.80

0.90

1.00

CFM

WATTS

CFM

WATTS

CFM

WATTS

CFM

WATTS

CFM

WATTS

CFM

WATTS

CFM

WATTS

CFM

WATTS

CFM

WATTS

CFM

WATTS

BHH

SPEED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HI

668

401

652

386

018

MED

654

233

541

209

 

LOW

702

220

641

206

536

183

 

HI

987

507

873

493

760

480

024

MED

935

338

867

322

800

304

733

286

867

268

 

LOW

900

290

850

287

800

243

760

220

697

238

843

183

 

HI

1200

640

1100

620

987

507

873

493

760

480

030

MED

1200

390

1134

397

1068

368

1002

367

936

339

897

322

800

304

 

LOW

900

280

850

267

800

243

 

HI

1414

617

1317

688

1219

660

1116

533

1013

507

910

480

036

MED

1472

647

1394

626

1297

495

1199

465

1102

435

985

397

 

LOW

1462

526

1400

506

1337

486

1275

467

1167

440

1100

414

1012

387

 

HI

1706

807

1637

782

1569

757

1500

732

042

MED

1736

733

1668

706

1599

680

1531

653

1434

622

1337

591

1240

560

 

LOW

1544

620

1508

610

1472

600

1436

590

1375

573

1313

557

1252

540

1172

517

1062

493

 

HI

1947

882

1867

857

1786

832

1706

807

1637

782

1569

757

1500

732

048

MED

1876

752

1829

772

1783

753

1736

733

1968

706

1599

680

1531

663

1434

622

1337

581

1240

560

 

LOW

1544

620

1508

610

1472

600

1436

590

1375

573

1313

557

1252

540

 

COOL TB2-A

1900

520

1900

573

1900

627

1900

680

1900

727

1900

773

1900

820

1900

863

1900

907

060

HEAT TB2-A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOL TB2-B

2000

590

2000

653

2000

717

2000

780

2000

833

2000

887

2000

940

2000

998

(230/460 only)

HEAT TB2-B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRIC

1750

400

1750

447

1750

493

1750

540

1750

593

1750

647

1750

700

1750

753

1750

807

1750

860

 

HEAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

060

HI

2499

1290

2391

1233

2283

1177

2175

1120

2067

1080

1958

1040

1850

1000

MED

2454

1163

2387

1117

2320

1070

2229

1023

2137

977

2046

930

1950

887

1854

843

1758

800

(575 ony)

LOW

2242

1090

2201

1053

2161

1017

2120

980

2041

927

1962

873

1883

820

1797

787

1711

753

1625

720

 

NOTE: Above data includes allowances for a dry indoor coil and no filters. For additional pressure drops, refer to the “Additional Static Pressure Resistance” table.

 

Continued

208 volts

 

 

 

 

 

 

 

 

EXTERNAL STATIC PRESSURE - IWG

 

 

 

 

 

 

MODEL NO.

MOTOR

.10

.20

.30

.40

.50

.60

.70

.80

.90

1.00

CFM

WATTS

CFM

WATTS

CFM

WATTS

CFM

WATTS

CFM

WATTS

CFM

WATTS

CFM

WATTS

CFM

WATTS

CFM

WATTS

CFM

WATTS

BHH

SPEED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HI

689

374

593

361

497

347

018

MED

690

231

659

210

487

188

 

LOW

741

226

686

212

632

198

577

185

453

165

 

HI

990

468

888

456

786

444

684

432

024

MED

961

351

902

321

841

305

751

290

720

274

660

257

 

LOW

810

261

765

240

720

219

675

198

627

215

 

HI

1171

604

1080

486

980

468

888

456

786

444

030

MED

1080

351

1021

341

961

331

902

321

841

306

781

280

 

LOW

810

261

766

240

 

HI

1440

608

1381

581

1273

656

1185

530

1097

604

1004

480

912

456

036

MED

1465

631

1395

512

1325

492

1255

473

1167

446

1079

419

952

392

 

LOW

1316

473

1260

455

1204

438

1148

420

1069

396

990

372

911

348

 

HI

1728

770

1644

740

1559

707

1474

673

1388

640

042

MED

1694

690

1662

673

1629

657

1597

640

1542

623

1408

607

1431

590

1336

563

1240

537

1195

510

 

LOW

1385

520

1349

510

1312

500

1276

490

1235

480

1193

470

1152

460

1079

440

 

HI

1982

870

1939

850

1897

830

1813

800

1728

770

1644

740

1559

707

1474

673

1389

—64

048

MED

1694

690

1662

673

1629

657

1597

640

1542

623

1486

607

1431

590

1336

563

1240

537

0

 

LOW

1385

520

1349

510

1312

500

1276

490

1235

480

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOL TB2-A

1900

520

1900

573

1900

627

1900

680

1900

727

1900

773

1900

820

 

HEAT TB2-A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

060

COOL TB2-B

2000

590

2000

653

2000

717

2000

780

2000

833

2000

877

 

HEAT TB2-B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRIC

1750

400

1750

447

1750

493

1750

540

1750

593

1750

647

1750

700

1750

753

 

HEAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: Above data includes allowances for a dry indoor coil and no filters. For additional pressure drops, refer to the “Additional Static Pressure Resistance” table.

12

Unitary Products Group

Page 12
Image 12
York THRU 060, B1HH018 installation instructions 230/460/575 volts, Side And Bottom Supply Air Blower Performance