York YK-ZCU2x0-0 Zoning System Setup Procedures, Zoning System Setup Options Menu Structure

Models: YK-ZCU2x0-0 YKSMU2x0-0 YK-ZCU4x0-0

1 96
Download 96 pages 17.58 Kb
Page 71
Image 71

428516-YUM-B-0908

Zoning System Setup Procedures

Zoning system setup procedures include:

Setting up a zoning system

Viewing zoning system status

Requesting instant shutdown of a zoning system

Balancing a zoning system

Figure 50 is a flowchart of the menu structure that is used to set up zoning systems on the System Manager. These menu selections are described in the sections that follow.

Setup

Systems

CV RTU

Zone

Coordinator

 

Coordinator Setup

and Status

System

Status

Setup

Zoning System

Status

• Control Mode

CV/COB RTU

Discharge Cooling Setpoint

Discharge Heating Setpoint

Min Number of Requests to Change Mode

Min Number of Urgent Requests to Change Mode

Min Time Before Changeover

Number of Cooling Stages

Number of Heating Stages

Static Pressure Setpoint

Balance System

Instant

Shutdown

Control Mode

VAV RTU

 

Discharge Air Temp Setpoint

 

 

Discharge Air Temp Strategy

 

 

Duct Static Setpoint

 

 

Duct Static Setpoint Reset

 

 

Duct Static Shutdown Limit

 

 

Max DAT Setpoint Adjust

 

 

Max Duct Static Setpoint Adjust

 

FIG:ZneSysStupFlw

• Morning Warm-up

 

Morning Warm-up Return Air Setpoint

Representative Zone

 

 

Unoccupied Heating/Cooling

 

 

 

 

 

 

Figure 50: Zoning System Setup Options - Menu Structure

System Manager/Zone Coordinator User’s Manual

71

Page 71
Image 71
York YK-ZCU2x0-0, YKSMU2x0-0, YK-ZCU4x0-0 Zoning System Setup Procedures, Zoning System Setup Options Menu Structure

YK-ZCU2x0-0, YKSMU2x0-0, YK-ZCU4x0-0 specifications

York YK chillers are known for their reliability, efficiency, and advanced technology, making them a popular choice for a wide range of commercial applications. Among the various models, the YK-ZCU4x0-0, YKSMU2x0-0, and YK-ZCU2x0-0 stand out for their innovative features and performance capabilities.

The YK-ZCU4x0-0 is designed to offer maximum cooling capacity while maintaining energy efficiency. One of its main features is the variable speed drive technology, which allows for precise control of the compressor speed based on real-time cooling demands. This technology not only enhances energy savings but also reduces wear and tear on components, extending the unit's lifespan. Additionally, the YK-ZCU4x0-0 is equipped with advanced microchannel heat exchanger technology, enabling better heat transfer and smaller refrigerant charges, which contributes to its lower environmental impact.

The YKSMU2x0-0 model is particularly notable for its integrated controls and monitoring systems. This chiller comes with a user-friendly touch screen interface that allows operators to monitor performance metrics and make adjustments with ease. The model features an intelligent control system that optimizes operational efficiency by adapting to changing load conditions. Moreover, its robust design makes it suitable for diverse applications, from data centers to manufacturing facilities, where reliability is crucial.

Finally, the YK-ZCU2x0-0 emphasizes modular design, which allows for easy installation and scalability. Its compact footprint makes it suitable for spaces with limited installation area. This model also supports modular redundancy, ensuring that if one module experiences issues, others can take over without disruption to the cooling process. The combination of high-efficiency performance, modularity, and state-of-the-art features makes the YK-ZCU2x0-0 an attractive option for facility managers looking for dependable chillers.

In summary, the York YK-ZCU4x0-0, YKSMU2x0-0, and YK-ZCU2x0-0 chillers represent the forefront of cooling technology, offering advanced features that cater to energy efficiency, flexibility, and operational reliability. Whether needing a robust solution for cooling large industrial spaces or a more compact unit for specific applications, these models provide the versatility and performance required in today's demanding environments.