80Configuration

Control Panel Parameters

Table 12 • Printer Parameters (Page 19 of 24)

Parameter Action/Explanation

Select Media Power-Up OptionThis parameter sets the action of the media when you turn on the printer.Default Value: CALIBRATIONSelections: CALIBRATION, SHORT CAL, LENGTH, NO MOTION,

FEED

Calibration adjusts sensor levels and thresholds, determines length, and feeds the media to the next web.

Short Cal sets media and web thresholds without adjusting sensor gain, determines length, and feeds the media to the next web.

Length determines label length using current sensor values, and feeds the media to the next web.

No Motion tells the printer not to move the media. You must manually ensure that the web is positioned correctly, or press feed to position the next web.

Feed—feeds the labels to the first registration point.

To change the value shown:

1.Press SELECT to select the parameter.

2.Press PLUS (+) or MINUS (-)to scroll through the options.

3.Press SELECT to accept any changes and deselect the parameter.

Select Head Close OptionThis parameter sets the action of the media when you close the printhead.

Default Value: CALIBRATION

Selections: CALIBRATION, SHORT CAL, LENGTH, NO MOTION,

FEED

Calibration adjusts sensor levels and thresholds, determines length, and feeds the media to the next web.

Short Cal sets media and web thresholds without adjusting sensor gain, determines length, and feeds the media to the next web.

Length determines label length using current sensor values, and feeds the media to the next web.

No Motion tells the printer not to move the media. You must manually ensure that the web is positioned correctly, or press feed to position the next web.

Feed—feeds the labels to the first registration point.

To change the value shown:

1.Press SELECT to select the parameter.

2.Press PLUS (+) or MINUS (-)to scroll through the options.

3.Press SELECT to accept any changes and deselect the parameter.

79695L-001 Rev. A

ZM400/ZM600 User Guide