Ductless Recirculating

Ductless recirculating is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a "purifying" hood rather than an exhaust hood. Fumes and exhaust from cooking is drawn and filtered by a set of optional charcoal filters. The air is then purified and re-circulated back within the home.

We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct work, if possible. The hood is most effective and efficient as an Exhaust unit. Only when the exhaust option is not possible should you recourse to converting the hood into a "purifying"unit.

When converted to be a "purifying" unit, a set of charcoal filters are required on top of its standard Metal Filter set. Order according to its Part number below. The standard Metal Filters are intended to capture residue from cooking and the optional charcoal filters help to purify fumes exhausted from cooking for re-circulation.

Ductless Recirculating

RECIRCULATING KIT (Required)

1. Kit includes charcoal filters and air diverter plate:

Hood Model:

Part No.

Filters in pkg.

 

 

 

 

ZVE-E30S

ZRC-0050

2

 

ZVE-E36S

ZRC-0051

3

 

ZVE-E42S

ZRC-0051

3

 

 

 

 

 

2.Remove metal filters on hood. Clip chacoal filters onto difuser panels.

3.Re-install metal filters.

4.Turn on filter change indicator on control panel (refer details pg. 7)

5.Charcoal filters must be replaced after every 120 hours of use (or approximately every 2 to 3 months based on the average of 1-2 hrs. of daily cooking time). The microprocessor in the controls when set, will elapsed and count usage time and indicate when carbon filter replacement is required every 120 hrs.

air diverter plate

6" straight pipe

wall pipe strap

Charcoal Filter Dimensions:

9 in x 6.4 in

228 mm x 162 mm

Ducting

1.Install a 6" straight pipe attached to the air diverter plate to divert air through louvers on duct cover.

Installation -

9

Page 11
Image 11
Zephyr ZVE-E42S Ductless Recirculating, Installation, RECIRCULATING KIT Required, Charcoal Filter Dimensions, Ducting