Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
TROUBLESHOOTING & REPAIR | |||||
| INVERTER BOARD VOLTAGE TEST (CONTINUED) |
| |||
| FIGURE F.10 – PLUG JP1 TESTPOINTS |
| |||
|
|
|
|
|
|
| 15 | 16 |
|
| |
| 13 | 14 |
|
| |
| 11 | 12 |
| JP1 | |
| 9 | 10 |
| ||
| 7 | 8 |
|
| |
| 5 | 6 |
|
| |
| 3 | 4 |
|
| |
|
|
|
|
|
|
PIN 1 PIN 2
INPUT BOARD
AC1
AC2
DC-
DC+
Return to Section TOC
to Section TOC
Return to Master TOC
to Master TOC
NOTE: DUE TO SAFETY REASONS AND THE PHYS- ICAL LOCATION OF THE INVERTER, IT IS NOT EASY TO PERFORM THE VOLTAGE TEST AT THE INVERTER BOARD. CHECKS CAN BE DONE AT THE INPUT BOARD CON- NECTOR JP1. See Fig. F.10.
PROCEDURE
1. Disconnect power to the INVERTEC® V155-S.
2. Perform the Case Cover Removal Procedure (left side only).
3. Connect the main 230VAC to the machine and switch ON the input switch.
4. Set the machine to STICK mode.
5. Locate the JP1 connector points. See figure F.10.
6. Using pins 8,9,16 or 15 as a common
Check pin
Check pin
Check pin
Check pin
Check pin
Check pin
7. Check to see if the correct microcontroller program is preset:
Return
Return