Lincoln Electric SVM192-A Installation, Technical Specifications Eagle 10,000 K2343-1,K2343-2

Page 8

TOC

TOC

A-2

INSTALLATION

A-2

TECHNICAL SPECIFICATIONS - EAGLE 10,000 (K2343-1,K2343-2)

INPUT - GASOLINE ENGINE

Return to Section

Return to Master

Make/Model

K2341-1

Kohler

CH20S

K2343-2

Kohler

Description

2cylinder 4 Cycle

Air-Cooled

Gasoline

Engine.

Aluminum Alloy

with Cast Iron

Liners,

Electronic Start

Horsepower

23HP@ 3600 RPM

Honda

Operating

Speed (RPM)

High Idle 3700

Full Load 3500

Displacement

cu. in.

(cu.cm.)

41(724)

Kohler

Starting Capacities System

12VDC

 

Battery

 

Electric Start

Fuel:

Group 58

Battery

9 Gal (34 L)

(435 cold

Lubricating Oil:

Cranking

2.0 Qts. (1.9 L)

Amps)

 

Return to Section TOC

Return to Master TOC

CH23HS

Low Idle 2200

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

RATED OUTPUT @ 104°F (40°C)- WELDER

Welding Output

DC Constant Current 210A / 25V / 100%

RATED OUTPUT @ 104°F (40°C)- GENERATOR

Auxiliary Power 1

9,000 Watts Continuous, 60 Hz AC

10,000 Watts Peak, 60 Hz AC (K2343-1)

10.500 Watts Peak, 60 Hz AC (K2343-2)

120/240 Volts

PHYSICAL DIMENSIONS

HEIGHT

WIDTH

DEPTH

WEIGHT

30.3 in.

19.1 in.

42.0 in.

502 lbs. (228kg)

770 mm

485 mm

1067 mm

 

 

 

 

 

1.Output rating in watts is equivalent to volt - amperes at unity factor.Output voltage is within +/-10% at all loads up to rated capacity. When welding available auxiliary power will be reduced.

EAGLE™ 10,000

Image 8
Contents Eagle 10,000 ISAFETYi Eagle 10,000Safety Electric Shock can kill ARC Rays can burnFumes and Gases Can be dangerousPowered equipment Welding CuttingCylinder may explode Sparks can cause fire or If damaged ExplosionPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcMaster Table of Contents for ALL Sections Table of Contents Installation Section Height Width Depth Weight InstallationTechnical Specifications Eagle 10,000 K2343-1,K2343-2 Safety Precautions Machine GroundingSpark Arrester TowingVehicle Mounting Fuel Gasoline Fuel onlyFollow vehicle manufacturer’s instructions Do not overfill tank, fuel expansion may cause overflowAdditional Safety Precautions High Altitude Operation Angle of OperationLifting Location / VentilationConnection of Lincoln Electric Wire Feeders Additional Safety PrecautionsInstructions Welder OperationAuxiliary Power 120/240 Volt Dual Voltage ReceptacleDuplex Receptacles Motor StartingElectrical Device USE with the Eagle 10,000 These Devices WithoutAdditional Resistive Type LoadsAuxiliary Power While Welding Simultaneous Welding and PowerStandby Power Connections Connection diagram shown Eagle 10,000Connection of Eagle 10,000 to Premises Wiring Figure A.1Table of Contents Operation Section Engine Switch OperationGeneral Description Welder Controls Function and OperationRange Switch OPERATIONB-3Eagle 10,000 Approximate Fuel Consumption Control DialSTARTING/SHUTDOWN Instructions BREAK-IN PeriodStarting the Engine Stopping the EngineWire Feed Welding Processes Welding ProcessTIG Constant Current Welding ARC GougingTypical Current Ranges 1 for Tungsten ELECTRODES2 Summary of Welding ProcessesTable of Contents Accessories Section K1745-1 GAS Cylinder Holder AccessoriesOptional Equipment Field Installed Wire Feed Recommended EquipmentPlasma Cutting Stick TIG WeldingEagle 10,000 Table of Contents Maintenance Section Maintenance Safety PrecautionsEngine OIL Change Engine OIL Refill CapacitiesAIR Cleaner and Other Maintenance OIL Filter ChangeEngine Adjustments Figure D.1 Major Component Locations Eagle 10,000 1TABLE of CONTENTS-THEORY of Operation Section E-1 BATTERY, STARTER, ENGINE, ROTOR, STATOR, and Idler Solenoid Theory of OperationRotor Field Feedback Auxiliary Power Figure E.3 Rotor Field Feedback and Auxiliary PowerWeld WINDING, REACTOR, and Range Switch Output BRIDGE, CHOKE, and Output Terminals1TABLE of Contents Troubleshooting and Repair F-1 2TROUBLESHOOTING and REPAIRF-2 HOW to USE Troubleshooting GuideTroubleshooting and Repair PC Board Troubleshooting ProceduresPerform the Rotor Voltage Test Problems Possible Areas Symptoms Misadjustments Recommended Course of ActionProblems Symptoms Possible Areas MisadjustmentsRotor Voltage2. PTestrform Engine Problems Wiring Charging Circuit Test BridgePerformTestthe. Output Rectifier Eagle 10,000 Materials Needed Rotor Voltage TestTest Description Rotor Voltage Test Test ProcedureRemove the case top, then reinstall the fuel cap Rotor Resistance Test Rotor Resistance Test Remove the case top, then replace the fuel capTroubleshooting and Repair Eagle 10,000 Auxiliary and Field Winding Test To test the 230 VAC winding Auxiliary and Field Winding TestTo test the 115 VAC winding To test the field winding Eagle 10,000 Output Rectifier Bridge Test Output Rectifier Bridge Test Figure F.4 Location of Output Rectifier LeadsCharging Circuit Test Charging Circuit Test Figure F.5 Location of Voltage RegulatorEngine Throttle Adjustment Test Engine Throttle Adjustment Test Strobe-tach MethodFigure F.7 Frequency Counter MethodEngine Throttle Adjustment Test Oscilloscope Method Vibratach MethodHigh Idle no Load Output Control AT Maximum Scope SettingsNormal Open Circuit Voltage Waveform 115VAC Supply Machine Loaded to 200 Amps AT 26 VDC Typical DC Weld Output Waveform CC ModeMachine Loaded Abnormal Open Circuit DC Weld Voltage Waveform Normal Open Circuit DC Weld Voltage Waveform CC Mode Brush Removal and Replacement Brush Removal and Replacement ProcedureSlip Rings Figure F.9 Brush LEADS/BRUSHES Retained with Cable TIEEagle 10,000 Printed Circuit Board Removal Replacement Replacement Printed Circuit Board RemovalTroubleshooting and Repair Eagle 10,000 43TROUBLESHOOTING and REPAIRF-43 Output Rectifier Bridge Removal Replacement44TROUBLESHOOTING and REPAIRF-44 Output Rectifier Bridge Removal45TROUBLESHOOTING and REPAIRF-45 Eagle 10,000 ENGINE/ROTOR Removal and Replacement InstructionsENGINE/ROTOR Removal and Replacement Figure F.12 Component LOCATIONS, ENGINE/ROTOR RemovalEngine and Rotor Removal Procedure Rotor Removal Procedure Figure F.13 Engine and Rotor Removed from Stator THRU-BOLTENGINE/ROTOR Removal Replacement KIT S20788Reassembly Procedure Auxiliary Power Receptacle OUTPUT1 Retest After RepairEngine Output Welder DC OUTPUT1Table of Contents Diagram Section Electrical Diagrams Eagle 10,000 KohlerWiring Diagram Code 11397 M21271 Schematic Complete Machine Code 11096 L12259 TerminalSchematic Complete Machine Code 11397 L13104 Torroid Core located onSchematic IDLER/FIELD Control P.C. Board L12197

SVM192-A specifications

Lincoln Electric's SVM192-A is a standout model in the sphere of welding machines, renowned for its advanced technology and versatility, making it a preferred choice among welding professionals and industrial applications. This single-phase inverter-based machine balances performance and portability, providing users with a reliable solution for a variety of welding tasks.

One of the key features of the SVM192-A is its capacity to perform multiple welding processes. It supports MIG, TIG, and stick welding, which allows users to switch between different techniques depending on the project requirements. This multi-functionality enhances the machine's utility, making it viable for various applications ranging from home projects to professional fabrication works.

The SVM192-A is equipped with Lincoln Electric’s proprietary technologies, including the advanced inverter technology, which ensures high efficiency and power output while maintaining a compact size. This inverter technology not only improves arc stability but also reduces power consumption and heat generation, making it a more eco-friendly option.

Key characteristics of the SVM192-A include a user-friendly digital display that provides clear settings for amperage, voltage, and other parameters, enabling precise control during welding. The machine also features a robust construction, designed to withstand tough working environments, ensuring longevity and minimal downtime.

Moreover, the SVM192-A incorporates safety features designed to protect the user and the machine, including overcurrent and thermal overload protection. This prioritization of safety ensures a worry-free operation, allowing welders to focus on their craft without the distraction of potential hazards.

Portability is another significant advantage of the SVM192-A. Weighing in at a lightweight design, it is easy to transport, making it ideal for mobile operations or jobs that require moving the equipment frequently.

In summary, the Lincoln Electric SVM192-A embodies versatility, efficiency, and durability, making it an exceptional choice for both novice and experienced welders. Its ability to handle multiple welding processes, combined with advanced technologies and user-friendly features, positions it as a top contender in the welding equipment market, suitable for a wide range of applications in various sectors.