=adjust maximum pressure valve B to the working value (in any case less than the safe maximum pressure the system can reach).

Pressure regulators with a volumetric valve (GCP ELETTRICO) Adjusting the maximum pressure valve

=put main control A in the drain position (“OFF”).

=loosen the hand wheel of maximum pressure valve B completely (anticlockwise).

=open volumetric valve E completely.

=start the pump by activating the power-takeoff of the tractor at 540rpm

=open main control A (position “ON”), the manometer will be activated

=open the drain tap on filter F slightly (only GCP ELETTRICO).

=close volumetric valve E completely. If the pressure rises over the maximum limit of the system, make sure maximum pressure valve B is open (see previous indications)

=open all of the section valves C (position “ON”)

=adjust maximum pressure valve B to a value over that of the working pressure (generally 10-14bar) and in any case lower than the safe maximum pressure that the system can reach.

Adjusting the volumetric pressure.

=with the volumetric pressure valve E adjust the pressure to the value the treatment will be done at (the pressure is indicated on the nozzles tables on the basis of the tractor speed and litres/hectare to spray)

Warning! The working pressure must be adjusted with the volumetric valve and not with the maximum pressure valve. In the case the working pressure is too near to the calibrated pressure of the maximum pressure valve, the proportional valve may not be able to compensate the speed variations correctly.

Adjusting the compensated returns

=close only one tap of section C (position “OFF”).

=adjust the corresponding compensator G until you return to the pressure set previously (displayed on the manometer).

=open and close the tap of section C and check that the pressure remains constant.

=repeat the above operations for all the section taps.

If the types of nozzles aren’t changed the regulations carried out will guarantee a constant spraying of the liquid also per treatments that are done at different working pressures.

NB: if the type of nozzle is changed then the calibrating will have to be done again.

4.8.3 DELIVERY FILTERS (ONLY EQUIPPED MODELS)

This is particularly useful when using small nozzles (low volume), they are normally mounted on the jet booms and have a filter cartridge with a 40-gauge mesh (the equivalent of a 0.4 mm hole).

At the end of each treatment cycle you should clean the cartridge: turn the jets to the closed position, put the command under pressure and open the tap under the filter to drain the tank for a few minutes.

You should clean the cartridge by hand periodically, on the basis of the product used. Stop the pump to clean. Wear rubber gloves and the other personal protective equipment when cleaning.

4.9AUXILIARIES TAPS BLOCK

A collector is installed (FIG. 9) in the Airdrop machines with taps for the utilities and accessories, which require a working pressure that is independent from the spraying pressure:

-Tank washing jet: see paragraph 4.13.1

-Ejector: see paragraph 4.10

-Agitators (2 independent taps): see paragraph 4.12

The taps are identified by the relevant sticker and the methods of use are described in the paragraphs indicated.

The pressure is normally regulated to 30-35 bar with the relevant valve (using a yellow knob) and displayed on the manometer installed; opening the utilities makes the pressure drop.

FIG. 9

Tank rinsing

Ejector

Agitator 1

Agitator 2

unigreen 13

Image 13
Contents 09/2006 USE and Maintenance ManualSummary Hand Lances Maintenance Guarantee Using and Keeping the USE and Maintenance ManualComposition of the Manual Product Responsibility Unigreen spa is not responsible ifKey to the symbols Intended USE Using Chemical ProductsProhibited USE Regulations for the USE of Chemical ProductsWeather Conditions Characteristics and SpecificationsDriving on the Road Tables of Fittings AllowedStandards of Reference Noise Level of the MachineInstructions Description of the MachineTransporting and Moving the Machine Preliminary ChecksTowed Atomisers Parking THREE-POINT Coupling Tractor CouplingFor verification use the formula shown here Hydraulic Connection to the DistributorsPump Cardan ShaftSuction Filter Components of the Pressure Regulator Pressure RegulatorControl box for GCP Elettrico electrical regulators General InstructionsAuxiliaries Taps Block Delivery Filters only Equipped ModelsTank rinsing Ejector Agitator Filling the Tank Test with Clean WaterManual Premixing Mixing12.2PREMIXER on Cover Optional 12.4COVER Washer for Chemical Containers13.1CIRCUIT Washer and Tank Washer Washing the AtomiserMultiplier FAN Unit Blower GroupClutch Minibar for Espalier Ventagli Fans CANOPY, and Espalier DistributorsSuper Spalliera for Espalier Hydraulics RV Boom for GDCOIL Feed from Tractor for hydraulic systems RV per GDCNON-DRIP Valve Spraying Description of the DiffusersDescription of the MFC Nozzles Mistblower CalibrationCalibrated Plates CP Batching Taps see PictureProgrammed Maintenance MaintenanceRoutine Maintenance Cleaning the NozzlesPutting Back Into Service After Winter Layup Extraordinary MaintenanceMultiplier Lubrication RepairsMaterials for Demolition Demolition and DisposalElectrical and Electronic Apparatus Waste Eeaw Tables for Calibrating Airdrop 2 Ventagli Fans Airdrop Calibrating TablesTables for Calibrating Airdrop 2 Ventagli + TOP Diffusors OptionalTables for Calibrating Airdrop Minibar Piastrina CalibrataTables for Calibrating Airdrop RV-GDC Tables for Calibrating Airdrop Super SpallieraTables of Delivery of Nozzles for Hand Lances 50 h 300 h Table of Programmed Maintenance OperationTAB a TAB.18A Allowed FittingsMember of the group