Unigreen Ventagli, Minibar, RV-GDC Components of the Pressure Regulator, General Instructions

Page 12

Don’t use the sprayer without having consulted the enclosed handbook.

12unigreen

4.8PRESSURE REGULATOR

To use the pressure regulator, follow the instructions in the enclosed handbook scrupulously. The pressure regulator controls all of the most important spraying functions, the thorough knowledge of its functions makes work easier and more precise.

The working pressure and the maximum pressure of the sprayer are determined by the pressure regulator which also protects the circuit from overpressure in any work conditions. (In serious but very rare cases, if the connecting pipes get blocked the pressure relief valve lets the pressure off) In some setups there may be a pump that can reach a pressure of 50 bar controlled by a regulator designed for 20 bar. In this case the maximum pressure that can be reached is 20 bar.

The regulators can be manual, mounted on the sprayer or at a distance to make the controls easier to use; or electrical with a control panel in the cabin. There are also regulator versions with mechanical remote controls with a cable. If the tractor has a waterproof cabin the use of electrical controls is obligatory.

4.8.1 COMPONENTS OF THE PRESSURE REGULATOR

Below you will find the indications for the main models fitted on Unigreen products.

A main ON-OFF command: “open” lets the fluid flow into the circuit in use; “closed” empties the tank.

B maximum pressure valve: adjusted by hand with the relevant knob (drains the excess liquid when the set pressure is reached).

C jets section tap: opens the corresponding jet boom or drains to the compensation regulator (G).

D auxiliary tap: can be used for various accessories (it is always manual). E volumetric pressure valve (proportional):

(when present) it regulates the spraying pressure. The valve automatically compensates variations in speed (within the scope of the same gear ratio), keeping the quantity of liquid supplied per surface unit (litres/hectare) unchanged.

Fself-cleaning filter: filters the delivery liquid.

G compensation regulators: suitably regulated, these make it possible to keep the pressure constant when one or more sections of jets is closed, they don’t influence treatments with the boom fully open.

Hmanometer: indicates the working pressure.

Connections:

R1 supply union

R2 drain union

R3 volumetric drain union

R4 jets section delivery union

R5 auxiliary delivery union

Control box for GCP ELETTRICO electrical regulators

I1 main control valve switch

I2 volumetric pressure valve switch (proportional)

I3 jets section valves switches

4.8.2 GENERAL INSTRUCTIONS

When using the pressure regulator, scrupulously observe the instructions in the enclosed handbook, below you will find generic indications for the major models fitted by Unigreen.

All the regulation and adjustment tests must be carried out with clean water.

Pressure regulators without a volumetric valve (GCP3-way - GRH-RVA) Adjusting the maximum pressure valve

=put main control A in the drain position (“OFF”).

=loosen the hand wheel of maximum pressure valve B completely (anticlockwise).

=start the pump by activating the power-takeoff of the tractor at 540rpm

=open main control A (position “ON”), the manometer will be activated

=open all of the section valves C (position “ON”)

Image 12
Contents USE and Maintenance Manual 09/2006Summary Hand Lances Maintenance Using and Keeping the USE and Maintenance Manual GuaranteeComposition of the Manual Product Responsibility Unigreen spa is not responsible ifKey to the symbols Using Chemical Products Intended USEProhibited USE Regulations for the USE of Chemical ProductsCharacteristics and Specifications Weather ConditionsDriving on the Road Tables of Fittings AllowedNoise Level of the Machine Standards of ReferenceInstructions Description of the MachinePreliminary Checks Transporting and Moving the MachineTowed Atomisers Parking Tractor Coupling THREE-POINT CouplingFor verification use the formula shown here Hydraulic Connection to the DistributorsCardan Shaft PumpSuction Filter Pressure Regulator Components of the Pressure RegulatorControl box for GCP Elettrico electrical regulators General InstructionsDelivery Filters only Equipped Models Auxiliaries Taps BlockTank rinsing Ejector Agitator Test with Clean Water Filling the TankMixing Manual Premixing12.2PREMIXER on Cover Optional 12.4COVER Washer for Chemical ContainersWashing the Atomiser 13.1CIRCUIT Washer and Tank WasherBlower Group Multiplier FAN UnitClutch Ventagli Fans CANOPY, and Espalier Distributors Minibar for EspalierSuper Spalliera for Espalier RV Boom for GDC HydraulicsOIL Feed from Tractor for hydraulic systems RV per GDCSpraying Description of the Diffusers NON-DRIP ValveDescription of the MFC Nozzles Mistblower CalibrationBatching Taps see Picture Calibrated Plates CPMaintenance Programmed MaintenanceRoutine Maintenance Cleaning the NozzlesExtraordinary Maintenance Putting Back Into Service After Winter LayupMultiplier Lubrication RepairsDemolition and Disposal Materials for DemolitionElectrical and Electronic Apparatus Waste Eeaw Airdrop Calibrating Tables Tables for Calibrating Airdrop 2 Ventagli FansOptional Tables for Calibrating Airdrop 2 Ventagli + TOP DiffusorsPiastrina Calibrata Tables for Calibrating Airdrop MinibarTables for Calibrating Airdrop Super Spalliera Tables for Calibrating Airdrop RV-GDCTables of Delivery of Nozzles for Hand Lances Table of Programmed Maintenance Operation 50 h 300 hTAB.18A Allowed Fittings TAB aMember of the group