4.12 MIXING

The active principle can be mixed using the relevant stirrers before and during the treatment. Correct mixing and stirring is the basis of the correct distribution on the crops. We recommend some useful accessories such as the premixer for powders and liquids (see the following paragraph).

The machines in the Airdrop-MFC range can be equipped with 2 hydro- pneumatic agitators, supplied by the relevant taps in the auxiliaries taps block (paragraph 4.9).

o mix the product in the tank run the stirrer (or ejector) for roughly 10-15 minutes at the maximum pressure available

4.12.1 MANUAL PREMIXING

Dilute the active principle by hand before introducing it into the tank, (you must wear suitable protective clothing such as rubber gloves, a mask or goggles, overalls, etc.).

WARNING: the indications to follow for using chemical products are indicated in paragraph 2.2.1.

4.12.2PREMIXER ON COVER (OPTIONAL):

Open the cover and pour all of the chemical powder into the filter, close the cover and open the supply tap until all of the powder has dissolved.

4.12.2PREMIXER ON COVER (OPTIONAL):

Open the cover and pour all of the chemical powder into the filter, close the cover and open the supply tap until all of the powder has dissolved.

4.12.4COVER WASHER FOR CHEMICAL CONTAINERS

The washer for chemical containers (FIG.15) is installed as standard in the hatch on the entire Airdrop-MFC range.

To wash the container, proceed as follows: -Lift the cover of the tank

-Open auxiliary tap (D) of the pressure regulator (see paragraph 4.8.1) supplying it with a pressure of under 8 bar

-Introduce the tin into the hopper, inserting the washing pipe into the tin. -Press the tin onto the pipe until it has been washed clean.

-At the end of the operations close the tap (D) of the pressure regulator again.

FIG. 13

FIG. 15

Box washing device on cover

unigreen 15

Image 15
Contents 09/2006 USE and Maintenance ManualSummary Hand Lances Maintenance Product Responsibility Unigreen spa is not responsible if Using and Keeping the USE and Maintenance ManualGuarantee Composition of the ManualKey to the symbols Regulations for the USE of Chemical Products Using Chemical ProductsIntended USE Prohibited USETables of Fittings Allowed Characteristics and SpecificationsWeather Conditions Driving on the RoadDescription of the Machine Noise Level of the MachineStandards of Reference InstructionsPreliminary Checks Transporting and Moving the MachineTowed Atomisers Parking Hydraulic Connection to the Distributors Tractor CouplingTHREE-POINT Coupling For verification use the formula shown hereCardan Shaft PumpSuction Filter General Instructions Pressure RegulatorComponents of the Pressure Regulator Control box for GCP Elettrico electrical regulatorsDelivery Filters only Equipped Models Auxiliaries Taps BlockTank rinsing Ejector Agitator Filling the Tank Test with Clean Water12.4COVER Washer for Chemical Containers MixingManual Premixing 12.2PREMIXER on Cover Optional13.1CIRCUIT Washer and Tank Washer Washing the AtomiserBlower Group Multiplier FAN UnitClutch Ventagli Fans CANOPY, and Espalier Distributors Minibar for EspalierSuper Spalliera for Espalier RV per GDC RV Boom for GDCHydraulics OIL Feed from Tractor for hydraulic systemsMistblower Calibration Spraying Description of the DiffusersNON-DRIP Valve Description of the MFC NozzlesCalibrated Plates CP Batching Taps see PictureCleaning the Nozzles MaintenanceProgrammed Maintenance Routine MaintenanceRepairs Extraordinary MaintenancePutting Back Into Service After Winter Layup Multiplier LubricationDemolition and Disposal Materials for DemolitionElectrical and Electronic Apparatus Waste Eeaw Tables for Calibrating Airdrop 2 Ventagli Fans Airdrop Calibrating TablesTables for Calibrating Airdrop 2 Ventagli + TOP Diffusors OptionalTables for Calibrating Airdrop Minibar Piastrina CalibrataTables for Calibrating Airdrop RV-GDC Tables for Calibrating Airdrop Super SpallieraTables of Delivery of Nozzles for Hand Lances 50 h 300 h Table of Programmed Maintenance OperationTAB a TAB.18A Allowed FittingsMember of the group