4.2PRELIMINARY CHECKS

When you receive the machine, check that it is complete and no parts are missing.

If there are any damaged parts, inform your local reseller or UNIGREEN directly in good time.

When the machine is delivered, make sure you ask:

a)that the machine is delivered with all of its parts fitted and that the fitting meets the requisites in table N° 18a (page 31).

This procedure is necessary because for reasons of space during transportation the machine is often delivered partially dismantled.

b)that it is tested in your presence in particular checking:

=that the suction filter and the inside of the tank are clean and free of work residues.

=that the connections are made correctly following the basic layout (FIG. N° 16, page 16).

=that the hose clips and all the unions and connections are tightened properly.

=that all of the protective covers are fitted solidly to the machine, in particular the protective cover of the power-takeoff of the pump.

=that the multiplier is sufficiently supplied with lubricant oil.

=that the zone where the fan turns hasn’t been bent by knocks during transportation.

4.3TRANSPORTING AND MOVING THE MACHINE

Every time you have to lift the machine, before starting the operation, always make sure the lifting gear and the relevant tools and equipment (cables, hooks, etc..) are suitable for lifting the load and check the stability of the same.

It is forbidden to unhook and move the machine with the tank full.

The dry weight of the machine at the maximum level of fitting and with all the accessories allowed is stamped on the nameplate (FIG.2); use slings and lifting gear with a adequate load-bearing capacity (FIG.3).

Never lift or move the mistblowers by hand if there is liquid in the tank. The machine will weigh more and the movement of the liquid can change the centre of gravity causing uncontrolled movements.

We recommend using slings as shown in the figure, the lifting points to use on the machine are indicated with the relevant symbol.

Don’t lift the machine with the forks of a forklift truck because the machine can tip over due to the overhanging weight of the blower group.

Don’t pass or stand under the machine when it is being lifted.

4.3.1TOWED ATOMISERS PARKING

Don’t stand the atomiser on unstable ground or steep slopes, the machine is designed to be parked safely on compact ground with a slope of up to 8.5°

MOVING

To lift the machine, follow the instructions above.

This symbol identifies the coupling points of the machine

FIG.3

Only move and lift the machine with the tank empty

unigreen 9

Image 9
Contents 09/2006 USE and Maintenance ManualSummary Hand Lances Maintenance Guarantee Using and Keeping the USE and Maintenance ManualComposition of the Manual Product Responsibility Unigreen spa is not responsible ifKey to the symbols Intended USE Using Chemical ProductsProhibited USE Regulations for the USE of Chemical ProductsWeather Conditions Characteristics and SpecificationsDriving on the Road Tables of Fittings AllowedStandards of Reference Noise Level of the MachineInstructions Description of the MachinePreliminary Checks Transporting and Moving the MachineTowed Atomisers Parking THREE-POINT Coupling Tractor CouplingFor verification use the formula shown here Hydraulic Connection to the DistributorsCardan Shaft PumpSuction Filter Components of the Pressure Regulator Pressure RegulatorControl box for GCP Elettrico electrical regulators General InstructionsDelivery Filters only Equipped Models Auxiliaries Taps BlockTank rinsing Ejector Agitator Filling the Tank Test with Clean WaterManual Premixing Mixing12.2PREMIXER on Cover Optional 12.4COVER Washer for Chemical Containers13.1CIRCUIT Washer and Tank Washer Washing the AtomiserBlower Group Multiplier FAN UnitClutch Ventagli Fans CANOPY, and Espalier Distributors Minibar for EspalierSuper Spalliera for Espalier Hydraulics RV Boom for GDCOIL Feed from Tractor for hydraulic systems RV per GDCNON-DRIP Valve Spraying Description of the DiffusersDescription of the MFC Nozzles Mistblower CalibrationCalibrated Plates CP Batching Taps see PictureProgrammed Maintenance MaintenanceRoutine Maintenance Cleaning the NozzlesPutting Back Into Service After Winter Layup Extraordinary MaintenanceMultiplier Lubrication RepairsDemolition and Disposal Materials for DemolitionElectrical and Electronic Apparatus Waste Eeaw Tables for Calibrating Airdrop 2 Ventagli Fans Airdrop Calibrating TablesTables for Calibrating Airdrop 2 Ventagli + TOP Diffusors OptionalTables for Calibrating Airdrop Minibar Piastrina CalibrataTables for Calibrating Airdrop RV-GDC Tables for Calibrating Airdrop Super SpallieraTables of Delivery of Nozzles for Hand Lances 50 h 300 h Table of Programmed Maintenance OperationTAB a TAB.18A Allowed FittingsMember of the group