significantly higher speeds, in general grease is used to lubricate bearings with a vertical or inclined axis as it stays in the zone for longer.

8.2.3 MULTIPLIER LUBRICATION

The multiplier and disengaging boxes are normally lubricated in an “oil bath”, in special cases NLGI n.0 grease is used. The viscosity is an essential characteristic of a lubricant oil and this is indicated by the SAE (SOCIETY OF AUTO-MOTIVE ENGINEERS) classification of the oils for gearboxes and differentials. Special additives improve the capacity of the oil to maintain a lubricant film also at high pressures and temperatures. We recommended using SAE 90 oil for the multiplier and disengaging boxes. The quantity of oil is established by the level cap. A greater quantity of oil doesn’t improve the conditions of lubrication and can cause overheating in the box. Changing the oil protects the parts from the dangers associated with wear and the presence of metallic particles that can be present, especially in the first period of use. We recommend replacing the oil after the first 50 working hours and then subsequently every 500 hours.

The quantity of oil needed is indicated on the sticker near the multiplier (FIG. 23)

WARNING: waste oil must not be dispersed in the environment, to dispo- FIG. 23 se of waste oil see paragraph 8.7.1.

8.3EXTRAORDINARY MAINTENANCE

At the end of a season of intense use, or every two years of normal use, it is a good idea to have a specialised service technician perform a general check on the machine.

8.4REPAIRS

We recommend having the normal UNIGREEN assistance service available from our reseller perform any repairs or contact a specialised workshop. During all of the repairs, in particular when welding, the machine and the circuit must be clean of any residues of chemical product.

If the machine has to be lifted (for example to change a wheel) follow the instructions in point 4.3 of the present handbook.

Also make sure the machine is stopped, connected to the tractor, and use the relevant chocks to block the wheel still on the ground.

If you use a jack (manual or hydraulic) make sure you use a jack that is suitable for the frame so it can’t slip and put it in the right position. The jack must be placed under the main frame of the machine near the wheel to change. Make sure the ground is compact: if necessary use wooden beams or other sufficiently resistant material to broaden the supporting base of the jack.

8.5STORAGE IN A WAREHOUSE AND TRANSPORTATION

The sprayer must be kept in a closed place away from excessive humidity and protected from frost. Especially if electrical pressure regulators, electrical motors, a spraying computer or similar components are fitted.

Before storing the machine, after you have washed it, apply a light coat of oil. If the temperature might drop to below zero, drain any residual liquid or add roughly 0.5 L of normal antifreeze for auto vehicles.

To transport the machine follow the instructions in point 4.3 of the present handbook.

8.6PUTTING BACK INTO SERVICE AFTER WINTER LAYUP

Before using the machine again after a long period of inactivity you should perform some general checks, following the instructions in point 4.2 and drain any antifreeze.

Never start the shaft of the pump if you think there may by ice inside. To check this, make sure you can turn the shaft by hand without connecting it to the tractor.

After you have connected the machine to the tractor (see point 4.4) following the instructions in the present user’s handbook and in the enclosures of the pump, pressure regulator and accessories.

unigreen 23

Image 23
Contents 09/2006 USE and Maintenance ManualSummary Hand Lances Maintenance Product Responsibility Unigreen spa is not responsible if Using and Keeping the USE and Maintenance ManualGuarantee Composition of the ManualKey to the symbols Regulations for the USE of Chemical Products Using Chemical ProductsIntended USE Prohibited USETables of Fittings Allowed Characteristics and SpecificationsWeather Conditions Driving on the RoadDescription of the Machine Noise Level of the MachineStandards of Reference InstructionsTowed Atomisers Parking Preliminary ChecksTransporting and Moving the Machine Hydraulic Connection to the Distributors Tractor CouplingTHREE-POINT Coupling For verification use the formula shown hereSuction Filter Cardan ShaftPump General Instructions Pressure RegulatorComponents of the Pressure Regulator Control box for GCP Elettrico electrical regulatorsTank rinsing Ejector Agitator Delivery Filters only Equipped ModelsAuxiliaries Taps Block Filling the Tank Test with Clean Water12.4COVER Washer for Chemical Containers MixingManual Premixing 12.2PREMIXER on Cover Optional13.1CIRCUIT Washer and Tank Washer Washing the AtomiserClutch Blower GroupMultiplier FAN Unit Super Spalliera for Espalier Ventagli Fans CANOPY, and Espalier DistributorsMinibar for Espalier RV per GDC RV Boom for GDCHydraulics OIL Feed from Tractor for hydraulic systemsMistblower Calibration Spraying Description of the DiffusersNON-DRIP Valve Description of the MFC NozzlesCalibrated Plates CP Batching Taps see PictureCleaning the Nozzles MaintenanceProgrammed Maintenance Routine MaintenanceRepairs Extraordinary MaintenancePutting Back Into Service After Winter Layup Multiplier LubricationElectrical and Electronic Apparatus Waste Eeaw Demolition and DisposalMaterials for Demolition Tables for Calibrating Airdrop 2 Ventagli Fans Airdrop Calibrating TablesTables for Calibrating Airdrop 2 Ventagli + TOP Diffusors OptionalTables for Calibrating Airdrop Minibar Piastrina CalibrataTables for Calibrating Airdrop RV-GDC Tables for Calibrating Airdrop Super SpallieraTables of Delivery of Nozzles for Hand Lances 50 h 300 h Table of Programmed Maintenance OperationTAB a TAB.18A Allowed FittingsMember of the group